Power 6/32 Unix version 1.2b
COMPUTER CONSOLES INC. INTER-OFFICE MEMO ----------------------------------------------------------------- Jan 7th, 1985 TO: Naresh Desai FR: Pham, Phuc M. SUBJECT: Report of Ethernet Controller Diagnostic Problems. Following are the problems of the ethernet controller functionality that I found while trying to develop a diagnostic program for it. 1. In loop 2 mode, the rbc of the receiver buffer are not updated to reflect the length of the buffered message, but instead, the crs (the first word of the receive buffer) always contains a value of 0xB000. This causes the error-checking mechanism to generate the following errors even though the message is corr- ectly received. - CRC error - Underrun error (because rbc = 0) - Oddbit error 2. In loop 3 mode, the crs word of the receive buffer always contains a value of 0xA000 which, again, causes the error checking mechanism to generate CRC and underrun errors for every message transmitted. Moreover, as seen in the attached sample run, no mess- age has shown up in the receive buffers.
This archive runs on limited infrastructure. Preserving old code on modern bandwidth. Automated agents are requested to crawl responsibly.