Annotation of cci/usr/src/usr.bin/f77/testf77/tests/FM373.f, revision 1.1.1.1

1.1       root        1: C***********************************************************************00010373
                      2: C     DATE***82/08/02*18.33.46
                      3: C     OWNER  PRE/850703/TC-85-   -410/    /FSTC/278FCVS*F78UBP20/
                      4: C     AUDIT  FCVS78 V2.0
                      5: C*****  FORTRAN 77                                                      00020373
                      6: C*****   FM373                                                          00030373
                      7: C*****                       XCOS - (189)                               00040373
                      8: C*****                                                                  00050373
                      9: C***********************************************************************00060373
                     10: C*****  GENERAL PURPOSE                                      SUBSET REF 00070373
                     11: C*****    TEST INTRINSIC FUNCTION COS                          15.3     00080373
                     12: C*****                                                        TABLE 5   00090373
                     13: C*****                                                                  00100373
                     14: CBB** ********************** BBCCOMNT **********************************00110373
                     15: C****                                                                   00120373
                     16: C****            1978 FORTRAN COMPILER VALIDATION SYSTEM                00130373
                     17: C****                          VERSION 2.0                              00140373
                     18: C****                                                                   00150373
                     19: C****                                                                   00160373
                     20: C****           SUGGESTIONS AND COMMENTS SHOULD BE FORWARDED TO         00170373
                     21: C****                   GENERAL SERVICES ADMINISTRATION                 00180373
                     22: C****                   FEDERAL SOFTWARE TESTING CENTER                 00190373
                     23: C****                   5203 LEESBURG PIKE, SUITE 1100                  00200373
                     24: C****                      FALLS CHURCH, VA. 22041                      00210373
                     25: C****                                                                   00220373
                     26: C****                          (703) 756-6153                           00230373
                     27: C****                                                                   00240373
                     28: CBE** ********************** BBCCOMNT **********************************00250373
                     29: CBB** ********************** BBCINITA **********************************00260373
                     30: C**** SPECIFICATION STATEMENTS                                          00270373
                     31: C****                                                                   00280373
                     32:       CHARACTER ZVERS*13, ZVERSD*17, ZDATE*17, ZPROG*5, ZCOMPL*20,      00290373
                     33:      1          ZNAME*20, ZTAPE*10, ZPROJ*13, REMRKS*31, ZTAPED*13      00300373
                     34: CBE** ********************** BBCINITA **********************************00310373
                     35: CBB** ********************** BBCINITB **********************************00320373
                     36: C**** INITIALIZE SECTION                                                00330373
                     37:       DATA  ZVERS,                  ZVERSD,             ZDATE           00340373
                     38:      1      /'VERSION 2.0  ',  '82/08/02*18.33.46',  '*NO DATE*TIME'/   00350373
                     39:       DATA       ZCOMPL,             ZNAME,             ZTAPE           00360373
                     40:      1      /'*NONE SPECIFIED*', '*NO COMPANY NAME*', '*NO TAPE*'/      00370373
                     41:       DATA       ZPROJ,           ZTAPED,         ZPROG                 00380373
                     42:      1      /'*NO PROJECT*',   '*NO TAPE DATE',  'XXXXX'/               00390373
                     43:       DATA   REMRKS /'                               '/                 00400373
                     44: C**** THE FOLLOWING 9 COMMENT LINES (CZ01, CZ02, ...) CAN BE REPLACED   00410373
                     45: C**** FOR IDENTIFYING THE TEST ENVIRONMENT                              00420373
                     46: C****                                                                   00430373
                     47: CZ01  ZVERS  = 'VERSION OF THE COMPILER VALIDATION SYSTEM'              00440373
                     48: CZ02  ZVERSD = 'CREATION DATE/TIME OF THE COMPILER VALIDATION SYSTEM'   00450373
                     49: CZ03  ZPROG  = 'PROGRAM NAME'                                           00460373
                     50:       ZDATE  = '07-Nov-85        '                                           *RP
                     51:       ZCOMPL = 'CCI 5.2             '                                        *RP
                     52:       ZPROJ  = 'TC-85-   -410'                                               *RP
                     53:       ZNAME  = '                    '                                        *RP
                     54:       ZTAPE  = '          '                                                  *RP
                     55:       ZTAPED = '850703       '                                               *RP
                     56: C                                                                       00530373
                     57:       IVPASS = 0                                                        00540373
                     58:       IVFAIL = 0                                                        00550373
                     59:       IVDELE = 0                                                        00560373
                     60:       IVINSP = 0                                                        00570373
                     61:       IVTOTL = 0                                                        00580373
                     62:       IVTOTN = 0                                                        00590373
                     63:       ICZERO = 0                                                        00600373
                     64: C                                                                       00610373
                     65: C     I01 CONTAINS THE LOGICAL UNIT NUMBER FOR THE CARD READER.         00620373
                     66:       I01 = 05                                                          00630373
                     67: C     I02 CONTAINS THE LOGICAL UNIT NUMBER FOR THE PRINTER.             00640373
                     68:       I02 = 06                                                          00650373
                     69: C                                                                       00660373
                     70:       I01 = 5                                                           00670373
                     71: C     THE CX010 CARD IS FOR OVERRIDING THE PROGRAM DEFAULT I01 = 5      00680373
                     72: CX011   REPLACED BY FEXEC X-011 CONTROL CARD.  CX011 IS FOR SYSTEMS     00690373
                     73: C     REQUIRING ADDITIONAL STATEMENTS FOR FILES ASSOCIATED WITH CX010.  00700373
                     74: C                                                                       00710373
                     75:       I02 = 6                                                           00720373
                     76: C     THE CX020 CARD IS FOR OVERRIDING THE PROGRAM DEFAULT I02= 6       00730373
                     77: CX021   REPLACED BY FEXEC X-021 CONTROL CARD.  CX021 IS FOR SYSTEMS     00740373
                     78: C     REQUIRING ADDITIONAL STATEMENTS FOR FILES ASSOCIATED WITH CX020.  00750373
                     79: C                                                                       00760373
                     80: CBE** ********************** BBCINITB **********************************00770373
                     81:       NUVI = I02                                                        00780373
                     82:       IVTOTL = 19                                                       00790373
                     83:       ZPROG = 'FM373'                                                   00800373
                     84: CBB** ********************** BBCHED0A **********************************00810373
                     85: C****                                                                   00820373
                     86: C**** WRITE REPORT TITLE                                                00830373
                     87: C****                                                                   00840373
                     88:       WRITE (I02, 90002)                                                00850373
                     89:       WRITE (I02, 90006)                                                00860373
                     90:       WRITE (I02, 90007)                                                00870373
                     91:       WRITE (I02, 90008)  ZVERS, ZVERSD                                 00880373
                     92:       WRITE (I02, 90009)  ZPROG, ZPROG                                  00890373
                     93:       WRITE (I02, 90010)  ZDATE, ZCOMPL                                 00900373
                     94: CBE** ********************** BBCHED0A **********************************00910373
                     95: C*****                                                                  00920373
                     96: C*****    HEADER FOR SEGMENT 189                                        00930373
                     97:         WRITE(NUVI,18900)                                               00940373
                     98: 18900   FORMAT(1H /33H XCOS - (189) INTRINSIC FUNCTIONS//               00950373
                     99:      1         14H  COS (COSINE)//                                      00960373
                    100:      2         20H  SUBSET REF. - 15.3)                                 00970373
                    101: CBB** ********************** BBCHED0B **********************************00980373
                    102: C**** WRITE DETAIL REPORT HEADERS                                       00990373
                    103: C****                                                                   01000373
                    104:       WRITE (I02,90004)                                                 01010373
                    105:       WRITE (I02,90004)                                                 01020373
                    106:       WRITE (I02,90013)                                                 01030373
                    107:       WRITE (I02,90014)                                                 01040373
                    108:       WRITE (I02,90015) IVTOTL                                          01050373
                    109: CBE** ********************** BBCHED0B **********************************01060373
                    110: C*****                                                                  01070373
                    111:         PIVS = 3.1415926535897932384626434                              01080373
                    112: C*****                                                                  01090373
                    113: CT001*  TEST 1                               ZERO (0.0), SINCE COS(0)=1 01100373
                    114:            IVTNUM = 1                                                   01110373
                    115:         BVS = 0.0                                                       01120373
                    116:         AVS = COS(BVS)                                                  01130373
                    117:            IF (AVS - 0.99995E+00) 20010, 10010, 40010                   01140373
                    118: 40010      IF (AVS - 0.10001E+01) 10010, 10010, 20010                   01150373
                    119: 10010      IVPASS = IVPASS + 1                                          01160373
                    120:            WRITE (NUVI, 80002) IVTNUM                                   01170373
                    121:            GO TO 0011                                                   01180373
                    122: 20010      IVFAIL = IVFAIL + 1                                          01190373
                    123:            RVCORR = 1.00000000000000                                    01200373
                    124:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      01210373
                    125:  0011      CONTINUE                                                     01220373
                    126: CT002*  TEST 2                                           VALUES NEAR PI 01230373
                    127:            IVTNUM = 2                                                   01240373
                    128:         AVS = COS(PIVS)                                                 01250373
                    129:            IF (AVS + 0.10001E+01) 20020, 10020, 40020                   01260373
                    130: 40020      IF (AVS + 0.99995E+00) 10020, 10020, 20020                   01270373
                    131: 10020      IVPASS = IVPASS + 1                                          01280373
                    132:            WRITE (NUVI, 80002) IVTNUM                                   01290373
                    133:            GO TO 0021                                                   01300373
                    134: 20020      IVFAIL = IVFAIL + 1                                          01310373
                    135:            RVCORR = -1.00000000000000                                   01320373
                    136:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      01330373
                    137:  0021      CONTINUE                                                     01340373
                    138: CT003*  TEST 3                                                PI - 1/16 01350373
                    139:            IVTNUM = 3                                                   01360373
                    140:         BVS = 3.0790926536                                              01370373
                    141:         AVS = COS(BVS)                                                  01380373
                    142:            IF (AVS + 0.99810E+00) 20030, 10030, 40030                   01390373
                    143: 40030      IF (AVS + 0.99799E+00) 10030, 10030, 20030                   01400373
                    144: 10030      IVPASS = IVPASS + 1                                          01410373
                    145:            WRITE (NUVI, 80002) IVTNUM                                   01420373
                    146:            GO TO 0031                                                   01430373
                    147: 20030      IVFAIL = IVFAIL + 1                                          01440373
                    148:            RVCORR = -0.99804751070010                                   01450373
                    149:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      01460373
                    150:  0031      CONTINUE                                                     01470373
                    151: CT004*  TEST 4                                                PI + 1/32 01480373
                    152:            IVTNUM = 4                                                   01490373
                    153:         AVS = COS(3.1728426535)                                         01500373
                    154:            IF (AVS + 0.99957E+00) 20040, 10040, 40040                   01510373
                    155: 40040      IF (AVS + 0.99946E+00) 10040, 10040, 20040                   01520373
                    156: 10040      IVPASS = IVPASS + 1                                          01530373
                    157:            WRITE (NUVI, 80002) IVTNUM                                   01540373
                    158:            GO TO 0041                                                   01550373
                    159: 20040      IVFAIL = IVFAIL + 1                                          01560373
                    160:            RVCORR = -0.99951175848514                                   01570373
                    161:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      01580373
                    162:  0041      CONTINUE                                                     01590373
                    163: CT005*  TEST 5                                         VALUES NEAR 2*PI 01600373
                    164:            IVTNUM = 5                                                   01610373
                    165:         BVS = PIVS * 2.0                                                01620373
                    166:         AVS = COS(BVS)                                                  01630373
                    167:            IF (AVS - 0.99995E+00) 20050, 10050, 40050                   01640373
                    168: 40050      IF (AVS - 0.10001E+01) 10050, 10050, 20050                   01650373
                    169: 10050      IVPASS = IVPASS + 1                                          01660373
                    170:            WRITE (NUVI, 80002) IVTNUM                                   01670373
                    171:            GO TO 0051                                                   01680373
                    172: 20050      IVFAIL = IVFAIL + 1                                          01690373
                    173:            RVCORR = 1.00000000000000                                    01700373
                    174:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      01710373
                    175:  0051      CONTINUE                                                     01720373
                    176: CT006*  TEST 6                                         VALUES NEAR 2*PI 01730373
                    177:            IVTNUM = 6                                                   01740373
                    178:         BVS = (2.0 * PIVS) - 1.0 / 64.0                                 01750373
                    179:         AVS = COS(BVS)                                                  01760373
                    180:            IF (AVS - 0.99982E+00) 20060, 10060, 40060                   01770373
                    181: 40060      IF (AVS - 0.99993E+00) 10060, 10060, 20060                   01780373
                    182: 10060      IVPASS = IVPASS + 1                                          01790373
                    183:            WRITE (NUVI, 80002) IVTNUM                                   01800373
                    184:            GO TO 0061                                                   01810373
                    185: 20060      IVFAIL = IVFAIL + 1                                          01820373
                    186:            RVCORR = 0.99987793217101                                    01830373
                    187:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      01840373
                    188:  0061      CONTINUE                                                     01850373
                    189: CT007*  TEST 7                                         VALUES NEAR 2*PI 01860373
                    190:            IVTNUM = 7                                                   01870373
                    191:         BVS = (2.0 * PIVS) + 1.0 / 128.0                                01880373
                    192:         AVS = COS(BVS)                                                  01890373
                    193:            IF (AVS - 0.99992E+00) 20070, 10070, 40070                   01900373
                    194: 40070      IF (AVS - 0.10001E+01) 10070, 10070, 20070                   01910373
                    195: 10070      IVPASS = IVPASS + 1                                          01920373
                    196:            WRITE (NUVI, 80002) IVTNUM                                   01930373
                    197:            GO TO 0071                                                   01940373
                    198: 20070      IVFAIL = IVFAIL + 1                                          01950373
                    199:            RVCORR = 0.99996948257710                                    01960373
                    200:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      01970373
                    201:  0071      CONTINUE                                                     01980373
                    202: CT008*  TEST 8                           AN EXPRESSION PRESENTED TO COS 01990373
                    203:            IVTNUM = 8                                                   02000373
                    204:         BVS = 350.0                                                     02010373
                    205:         AVS = COS(BVS / 100.0)                                          02020373
                    206:            IF (AVS + 0.93651E+00) 20080, 10080, 40080                   02030373
                    207: 40080      IF (AVS + 0.93641E+00) 10080, 10080, 20080                   02040373
                    208: 10080      IVPASS = IVPASS + 1                                          02050373
                    209:            WRITE (NUVI, 80002) IVTNUM                                   02060373
                    210:            GO TO 0081                                                   02070373
                    211: 20080      IVFAIL = IVFAIL + 1                                          02080373
                    212:            RVCORR = -0.93645668729080                                   02090373
                    213:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      02100373
                    214:  0081      CONTINUE                                                     02110373
                    215: CT009*  TEST 9                                      A NEGATIVE ARGUMENT 02120373
                    216:            IVTNUM = 9                                                   02130373
                    217:         BVS = -1.5                                                      02140373
                    218:         AVS = COS(BVS)                                                  02150373
                    219:            IF (AVS - 0.70733E-01) 20090, 10090, 40090                   02160373
                    220: 40090      IF (AVS - 0.70741E-01) 10090, 10090, 20090                   02170373
                    221: 10090      IVPASS = IVPASS + 1                                          02180373
                    222:            WRITE (NUVI, 80002) IVTNUM                                   02190373
                    223:            GO TO 0091                                                   02200373
                    224: 20090      IVFAIL = IVFAIL + 1                                          02210373
                    225:            RVCORR = 0.07073720166770                                    02220373
                    226:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      02230373
                    227:  0091      CONTINUE                                                     02240373
                    228: CT010*  TEST 10                TEST LARGE VALUES FOR ARGUMENT REDUCTION 02250373
                    229:            IVTNUM = 10                                                  02260373
                    230:         AVS = COS(200.0)                                                02270373
                    231:            IF (AVS - 0.48716E+00) 20100, 10100, 40100                   02280373
                    232: 40100      IF (AVS - 0.48722E+00) 10100, 10100, 20100                   02290373
                    233: 10100      IVPASS = IVPASS + 1                                          02300373
                    234:            WRITE (NUVI, 80002) IVTNUM                                   02310373
                    235:            GO TO 0101                                                   02320373
                    236: 20100      IVFAIL = IVFAIL + 1                                          02330373
                    237:            RVCORR = 0.48718767500701                                    02340373
                    238:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      02350373
                    239:  0101      CONTINUE                                                     02360373
                    240: CT011*  TEST 11                TEST LARGE VALUES FOR ARGUMENT REDUCTION 02370373
                    241:            IVTNUM = 11                                                  02380373
                    242:         AVS = COS(-31416.0)                                             02390373
                    243:            IF (AVS - 0.99725E+00) 20110, 10110, 40110                   02400373
                    244: 40110      IF (AVS - 0.99736E+00) 10110, 10110, 20110                   02410373
                    245: 10110      IVPASS = IVPASS + 1                                          02420373
                    246:            WRITE (NUVI, 80002) IVTNUM                                   02430373
                    247:            GO TO 0111                                                   02440373
                    248: 20110      IVFAIL = IVFAIL + 1                                          02450373
                    249:            RVCORR = 0.99730272627420                                    02460373
                    250:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      02470373
                    251:  0111      CONTINUE                                                     02480373
                    252: CT012*  TEST 12                                   TEST VALUES NEAR PI/2 02490373
                    253:            IVTNUM = 12                                                  02500373
                    254:         AVS = COS(1.5707963268)                                         02510373
                    255:            IF (AVS + 0.50000E-04) 20120, 10120, 40120                   02520373
                    256: 40120      IF (AVS - 0.50000E-04) 10120, 10120, 20120                   02530373
                    257: 10120      IVPASS = IVPASS + 1                                          02540373
                    258:            WRITE (NUVI, 80002) IVTNUM                                   02550373
                    259:            GO TO 0121                                                   02560373
                    260: 20120      IVFAIL = IVFAIL + 1                                          02570373
                    261:            RVCORR = 0.00000000000000                                    02580373
                    262:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      02590373
                    263:  0121      CONTINUE                                                     02600373
                    264: CT013*  TEST 13                                         (PI / 2) - 1/32 02610373
                    265:            IVTNUM = 13                                                  02620373
                    266:         BVS = (1.5395463267)                                            02630373
                    267:         AVS = COS(BVS)                                                  02640373
                    268:            IF (AVS - 0.31243E-01) 20130, 10130, 40130                   02650373
                    269: 40130      IF (AVS - 0.31247E-01) 10130, 10130, 20130                   02660373
                    270: 10130      IVPASS = IVPASS + 1                                          02670373
                    271:            WRITE (NUVI, 80002) IVTNUM                                   02680373
                    272:            GO TO 0131                                                   02690373
                    273: 20130      IVFAIL = IVFAIL + 1                                          02700373
                    274:            RVCORR = 0.03124491398533                                    02710373
                    275:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      02720373
                    276:  0131      CONTINUE                                                     02730373
                    277: CT014*  TEST 14                                         (PI / 2) + 1/16 02740373
                    278:            IVTNUM = 14                                                  02750373
                    279:         AVS = COS(1.6332963267)                                         02760373
                    280:            IF (AVS + 0.62463E-01) 20140, 10140, 40140                   02770373
                    281: 40140      IF (AVS + 0.62456E-01) 10140, 10140, 20140                   02780373
                    282: 10140      IVPASS = IVPASS + 1                                          02790373
                    283:            WRITE (NUVI, 80002) IVTNUM                                   02800373
                    284:            GO TO 0141                                                   02810373
                    285: 20140      IVFAIL = IVFAIL + 1                                          02820373
                    286:            RVCORR = -0.06245931784238                                   02830373
                    287:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      02840373
                    288:  0141      CONTINUE                                                     02850373
                    289: CT015*  TEST 15                                 TEST VALUES NEAR 3*PI/2 02860373
                    290:            IVTNUM = 15                                                  02870373
                    291:         BVS = 3.0 * PIVS / 2.0                                          02880373
                    292:         AVS = COS(BVS)                                                  02890373
                    293:            IF (AVS + 0.50000E-04) 20150, 10150, 40150                   02900373
                    294: 40150      IF (AVS - 0.50000E-04) 10150, 10150, 20150                   02910373
                    295: 10150      IVPASS = IVPASS + 1                                          02920373
                    296:            WRITE (NUVI, 80002) IVTNUM                                   02930373
                    297:            GO TO 0151                                                   02940373
                    298: 20150      IVFAIL = IVFAIL + 1                                          02950373
                    299:            RVCORR = 0.00000000000000                                    02960373
                    300:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      02970373
                    301:  0151      CONTINUE                                                     02980373
                    302: CT016*  TEST 16                                 TEST VALUES NEAR 3*PI/2 02990373
                    303:            IVTNUM = 16                                                  03000373
                    304:         BVS = (3.0 * PIVS / 2.0) - 1.0 / 16.0                           03010373
                    305:         AVS = COS(BVS)                                                  03020373
                    306:            IF (AVS + 0.62463E-01) 20160, 10160, 40160                   03030373
                    307: 40160      IF (AVS + 0.62456E-01) 10160, 10160, 20160                   03040373
                    308: 10160      IVPASS = IVPASS + 1                                          03050373
                    309:            WRITE (NUVI, 80002) IVTNUM                                   03060373
                    310:            GO TO 0161                                                   03070373
                    311: 20160      IVFAIL = IVFAIL + 1                                          03080373
                    312:            RVCORR = -0.06245931784238                                   03090373
                    313:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      03100373
                    314:  0161      CONTINUE                                                     03110373
                    315: CT017*  TEST 17                                 TEST VALUES NEAR 3*PI/2 03120373
                    316:            IVTNUM = 17                                                  03130373
                    317:         BVS = (3.0 * PIVS / 2.0) + 1.0 / 512.0                          03140373
                    318:         AVS = COS(BVS)                                                  03150373
                    319:            IF (AVS - 0.19530E-02) 20170, 10170, 40170                   03160373
                    320: 40170      IF (AVS - 0.19533E-02) 10170, 10170, 20170                   03170373
                    321: 10170      IVPASS = IVPASS + 1                                          03180373
                    322:            WRITE (NUVI, 80002) IVTNUM                                   03190373
                    323:            GO TO 0171                                                   03200373
                    324: 20170      IVFAIL = IVFAIL + 1                                          03210373
                    325:            RVCORR = 0.00195312375824                                    03220373
                    326:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      03230373
                    327: 70171      FORMAT (1H ,16X,34HINFORMATIVE - UNDER REVIEW BY FSTC)       03230*TI
                    328:            WRITE (NUVI,70171)                                           03230*TI
                    329:  0171      CONTINUE                                                     03240373
                    330: CT018*  TEST 18                               ARGUMENT OF LOW MAGNITUDE 03250373
                    331:            IVTNUM = 18                                                  03260373
                    332:         BVS = -3.141593E-35                                             03270373
                    333:         AVS = COS(BVS)                                                  03280373
                    334:            IF (AVS - 0.99995E+00) 20180, 10180, 40180                   03290373
                    335: 40180      IF (AVS - 0.10001E+01) 10180, 10180, 20180                   03300373
                    336: 10180      IVPASS = IVPASS + 1                                          03310373
                    337:            WRITE (NUVI, 80002) IVTNUM                                   03320373
                    338:            GO TO 0181                                                   03330373
                    339: 20180      IVFAIL = IVFAIL + 1                                          03340373
                    340:            RVCORR = 1.00000000000000                                    03350373
                    341:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      03360373
                    342:  0181      CONTINUE                                                     03370373
                    343: CT019*  TEST 19                              THE FUNCTION APPLIED TWICE 03380373
                    344:            IVTNUM = 19                                                  03390373
                    345:         AVS = COS(PIVS / 4.0) * COS(3.0 * PIVS / 4.0)                   03400373
                    346:            IF (AVS + 0.50003E+00) 20190, 10190, 40190                   03410373
                    347: 40190      IF (AVS + 0.49997E+00) 10190, 10190, 20190                   03420373
                    348: 10190      IVPASS = IVPASS + 1                                          03430373
                    349:            WRITE (NUVI, 80002) IVTNUM                                   03440373
                    350:            GO TO 0191                                                   03450373
                    351: 20190      IVFAIL = IVFAIL + 1                                          03460373
                    352:            RVCORR = -0.50000000000000                                   03470373
                    353:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      03480373
                    354:  0191      CONTINUE                                                     03490373
                    355: C*****                                                                  03500373
                    356: CBB** ********************** BBCSUM0  **********************************03510373
                    357: C**** WRITE OUT TEST SUMMARY                                            03520373
                    358: C****                                                                   03530373
                    359:       IVTOTN = IVPASS + IVFAIL + IVDELE + IVINSP                        03540373
                    360:       WRITE (I02, 90004)                                                03550373
                    361:       WRITE (I02, 90014)                                                03560373
                    362:       WRITE (I02, 90004)                                                03570373
                    363:       WRITE (I02, 90020) IVPASS                                         03580373
                    364:       WRITE (I02, 90022) IVFAIL                                         03590373
                    365:       WRITE (I02, 90024) IVDELE                                         03600373
                    366:       WRITE (I02, 90026) IVINSP                                         03610373
                    367:       WRITE (I02, 90028) IVTOTN, IVTOTL                                 03620373
                    368: CBE** ********************** BBCSUM0  **********************************03630373
                    369: CBB** ********************** BBCFOOT0 **********************************03640373
                    370: C**** WRITE OUT REPORT FOOTINGS                                         03650373
                    371: C****                                                                   03660373
                    372:       WRITE (I02,90016) ZPROG, ZPROG                                    03670373
                    373:       WRITE (I02,90018) ZPROJ, ZNAME, ZTAPE, ZTAPED                     03680373
                    374:       WRITE (I02,90019)                                                 03690373
                    375: CBE** ********************** BBCFOOT0 **********************************03700373
                    376: CBB** ********************** BBCFMT0A **********************************03710373
                    377: C**** FORMATS FOR TEST DETAIL LINES                                     03720373
                    378: C****                                                                   03730373
                    379: 80000 FORMAT (1H ,2X,I3,4X,7HDELETED,32X,A31)                           03740373
                    380: 80002 FORMAT (1H ,2X,I3,4X,7H PASS  ,32X,A31)                           03750373
                    381: 80004 FORMAT (1H ,2X,I3,4X,7HINSPECT,32X,A31)                           03760373
                    382: 80008 FORMAT (1H ,2X,I3,4X,7H FAIL  ,32X,A31)                           03770373
                    383: 80010 FORMAT (1H ,2X,I3,4X,7H FAIL  ,/,1H ,15X,10HCOMPUTED= ,           03780373
                    384:      1I6,/,1H ,15X,10HCORRECT=  ,I6)                                    03790373
                    385: 80012 FORMAT (1H ,2X,I3,4X,7H FAIL  ,/,1H ,16X,10HCOMPUTED= ,           03800373
                    386:      1E12.5,/,1H ,16X,10HCORRECT=  ,E12.5)                              03810373
                    387: 80018 FORMAT (1H ,2X,I3,4X,7H FAIL  ,/,1H ,16X,10HCOMPUTED= ,           03820373
                    388:      1A21,/,1H ,16X,10HCORRECT=  ,A21)                                  03830373
                    389: 80020 FORMAT (1H ,16X,10HCOMPUTED= ,A21,1X,A31)                         03840373
                    390: 80022 FORMAT (1H ,16X,10HCORRECT=  ,A21,1X,A31)                         03850373
                    391: 80024 FORMAT (1H ,16X,10HCOMPUTED= ,I6,16X,A31)                         03860373
                    392: 80026 FORMAT (1H ,16X,10HCORRECT=  ,I6,16X,A31)                         03870373
                    393: 80028 FORMAT (1H ,16X,10HCOMPUTED= ,E12.5,10X,A31)                      03880373
                    394: 80030 FORMAT (1H ,16X,10HCORRECT=  ,E12.5,10X,A31)                      03890373
                    395: 80050 FORMAT (1H ,48X,A31)                                              03900373
                    396: CBE** ********************** BBCFMT0A **********************************03910373
                    397: CBB** ********************** BBCFMT0B **********************************03920373
                    398: C**** FORMAT STATEMENTS FOR PAGE HEADERS                                03930373
                    399: C****                                                                   03940373
                    400: 90002 FORMAT (1H1)                                                      03950373
                    401: 90004 FORMAT (1H )                                                      03960373
                    402: 90006 FORMAT (1H ,20X,31HFEDERAL SOFTWARE TESTING CENTER)               03970373
                    403: 90007 FORMAT (1H ,19X,34HFORTRAN COMPILER VALIDATION SYSTEM)            03980373
                    404: 90008 FORMAT (1H ,21X,A13,A17)                                          03990373
                    405: 90009 FORMAT (1H ,/,2H *,A5,6HBEGIN*,12X,15HTEST RESULTS - ,A5,/)       04000373
                    406: 90010 FORMAT (1H ,8X,16HTEST DATE*TIME= ,A17,15H  -  COMPILER= ,A20)    04010373
                    407: 90013 FORMAT (1H ,8H TEST   ,10HPASS/FAIL ,6X,17HDISPLAYED RESULTS,     04020373
                    408:      1       7X,7HREMARKS,24X)                                          04030373
                    409: 90014 FORMAT (1H ,46H----------------------------------------------,    04040373
                    410:      1        33H---------------------------------)                     04050373
                    411: 90015 FORMAT (1H ,48X,17HTHIS PROGRAM HAS ,I3,6H TESTS,/)               04060373
                    412: C****                                                                   04070373
                    413: C**** FORMAT STATEMENTS FOR REPORT FOOTINGS                             04080373
                    414: C****                                                                   04090373
                    415: 90016 FORMAT (1H ,/,2H *,A5,4HEND*,14X,14HEND OF TEST - ,A5,/)          04100373
                    416: 90018 FORMAT (1H ,A13,13X,A20,7H   *   ,A10,1H/,                        04110373
                    417:      1        A13)                                                      04120373
                    418: 90019 FORMAT (1H ,26HFOR OFFICIAL USE ONLY     ,35X,15HCOPYRIGHT  1982) 04130373
                    419: C****                                                                   04140373
                    420: C**** FORMAT STATEMENTS FOR RUN SUMMARY                                 04150373
                    421: C****                                                                   04160373
                    422: 90020 FORMAT (1H ,21X,I5,13H TESTS PASSED)                              04170373
                    423: 90022 FORMAT (1H ,21X,I5,13H TESTS FAILED)                              04180373
                    424: 90024 FORMAT (1H ,21X,I5,14H TESTS DELETED)                             04190373
                    425: 90026 FORMAT (1H ,21X,I5,25H TESTS REQUIRE INSPECTION)                  04200373
                    426: 90028 FORMAT (1H ,21X,I5,4H OF ,I3,15H TESTS EXECUTED)                  04210373
                    427: CBE** ********************** BBCFMT0B **********************************04220373
                    428: C*****                                                                  04230373
                    429: C*****    END OF TEST SEGMENT 189                                       04240373
                    430:       STOP                                                              04250373
                    431:       END                                                               04260373
                    432:                                                                         04270373

unix.superglobalmegacorp.com

This archive runs on limited infrastructure. Preserving old code on modern bandwidth. Automated agents are requested to crawl responsibly.