Annotation of cci/usr/src/usr.bin/f77/testf77/tests/FM379.f, revision 1.1.1.1

1.1       root        1: C***********************************************************************00010379
                      2: C     DATE***82/08/02*18.33.46
                      3: C     OWNER  PRE/850703/TC-85-   -410/    /FSTC/278FCVS*F78UBP20/
                      4: C     AUDIT  FCVS78 V2.0
                      5: C*****  FORTRAN 77                                                      00020379
                      6: C*****   FM379                                                          00030379
                      7: C*****                       XRFOR - (201)                              00040379
                      8: C*****                                                                  00050379
                      9: C***********************************************************************00060379
                     10: C*****  GENERAL PURPOSE                                      SUBSET REF 00070379
                     11: C*****    TEST TRIGONOMETRIC FORMULAE                          15.3     00080379
                     12: C*****                                                        TABLE 5   00090379
                     13: C*****                                                                  00100379
                     14: CBB** ********************** BBCCOMNT **********************************00110379
                     15: C****                                                                   00120379
                     16: C****            1978 FORTRAN COMPILER VALIDATION SYSTEM                00130379
                     17: C****                          VERSION 2.0                              00140379
                     18: C****                                                                   00150379
                     19: C****                                                                   00160379
                     20: C****           SUGGESTIONS AND COMMENTS SHOULD BE FORWARDED TO         00170379
                     21: C****                   GENERAL SERVICES ADMINISTRATION                 00180379
                     22: C****                   FEDERAL SOFTWARE TESTING CENTER                 00190379
                     23: C****                   5203 LEESBURG PIKE, SUITE 1100                  00200379
                     24: C****                      FALLS CHURCH, VA. 22041                      00210379
                     25: C****                                                                   00220379
                     26: C****                          (703) 756-6153                           00230379
                     27: C****                                                                   00240379
                     28: CBE** ********************** BBCCOMNT **********************************00250379
                     29: CBB** ********************** BBCINITA **********************************00260379
                     30: C**** SPECIFICATION STATEMENTS                                          00270379
                     31: C****                                                                   00280379
                     32:       CHARACTER ZVERS*13, ZVERSD*17, ZDATE*17, ZPROG*5, ZCOMPL*20,      00290379
                     33:      1          ZNAME*20, ZTAPE*10, ZPROJ*13, REMRKS*31, ZTAPED*13      00300379
                     34: CBE** ********************** BBCINITA **********************************00310379
                     35: CBB** ********************** BBCINITB **********************************00320379
                     36: C**** INITIALIZE SECTION                                                00330379
                     37:       DATA  ZVERS,                  ZVERSD,             ZDATE           00340379
                     38:      1      /'VERSION 2.0  ',  '82/08/02*18.33.46',  '*NO DATE*TIME'/   00350379
                     39:       DATA       ZCOMPL,             ZNAME,             ZTAPE           00360379
                     40:      1      /'*NONE SPECIFIED*', '*NO COMPANY NAME*', '*NO TAPE*'/      00370379
                     41:       DATA       ZPROJ,           ZTAPED,         ZPROG                 00380379
                     42:      1      /'*NO PROJECT*',   '*NO TAPE DATE',  'XXXXX'/               00390379
                     43:       DATA   REMRKS /'                               '/                 00400379
                     44: C**** THE FOLLOWING 9 COMMENT LINES (CZ01, CZ02, ...) CAN BE REPLACED   00410379
                     45: C**** FOR IDENTIFYING THE TEST ENVIRONMENT                              00420379
                     46: C****                                                                   00430379
                     47: CZ01  ZVERS  = 'VERSION OF THE COMPILER VALIDATION SYSTEM'              00440379
                     48: CZ02  ZVERSD = 'CREATION DATE/TIME OF THE COMPILER VALIDATION SYSTEM'   00450379
                     49: CZ03  ZPROG  = 'PROGRAM NAME'                                           00460379
                     50:       ZDATE  = '07-Nov-85        '                                           *RP
                     51:       ZCOMPL = 'CCI 5.2             '                                        *RP
                     52:       ZPROJ  = 'TC-85-   -410'                                               *RP
                     53:       ZNAME  = '                    '                                        *RP
                     54:       ZTAPE  = '          '                                                  *RP
                     55:       ZTAPED = '850703       '                                               *RP
                     56: C                                                                       00530379
                     57:       IVPASS = 0                                                        00540379
                     58:       IVFAIL = 0                                                        00550379
                     59:       IVDELE = 0                                                        00560379
                     60:       IVINSP = 0                                                        00570379
                     61:       IVTOTL = 0                                                        00580379
                     62:       IVTOTN = 0                                                        00590379
                     63:       ICZERO = 0                                                        00600379
                     64: C                                                                       00610379
                     65: C     I01 CONTAINS THE LOGICAL UNIT NUMBER FOR THE CARD READER.         00620379
                     66:       I01 = 05                                                          00630379
                     67: C     I02 CONTAINS THE LOGICAL UNIT NUMBER FOR THE PRINTER.             00640379
                     68:       I02 = 06                                                          00650379
                     69: C                                                                       00660379
                     70:       I01 = 5                                                           00670379
                     71: C     THE CX010 CARD IS FOR OVERRIDING THE PROGRAM DEFAULT I01 = 5      00680379
                     72: CX011   REPLACED BY FEXEC X-011 CONTROL CARD.  CX011 IS FOR SYSTEMS     00690379
                     73: C     REQUIRING ADDITIONAL STATEMENTS FOR FILES ASSOCIATED WITH CX010.  00700379
                     74: C                                                                       00710379
                     75:       I02 = 6                                                           00720379
                     76: C     THE CX020 CARD IS FOR OVERRIDING THE PROGRAM DEFAULT I02= 6       00730379
                     77: CX021   REPLACED BY FEXEC X-021 CONTROL CARD.  CX021 IS FOR SYSTEMS     00740379
                     78: C     REQUIRING ADDITIONAL STATEMENTS FOR FILES ASSOCIATED WITH CX020.  00750379
                     79: C                                                                       00760379
                     80: CBE** ********************** BBCINITB **********************************00770379
                     81:       NUVI = I02                                                        00780379
                     82:       IVTOTL = 10                                                       00790379
                     83:       ZPROG = 'FM379'                                                   00800379
                     84: CBB** ********************** BBCHED0A **********************************00810379
                     85: C****                                                                   00820379
                     86: C**** WRITE REPORT TITLE                                                00830379
                     87: C****                                                                   00840379
                     88:       WRITE (I02, 90002)                                                00850379
                     89:       WRITE (I02, 90006)                                                00860379
                     90:       WRITE (I02, 90007)                                                00870379
                     91:       WRITE (I02, 90008)  ZVERS, ZVERSD                                 00880379
                     92:       WRITE (I02, 90009)  ZPROG, ZPROG                                  00890379
                     93:       WRITE (I02, 90010)  ZDATE, ZCOMPL                                 00900379
                     94: CBE** ********************** BBCHED0A **********************************00910379
                     95: C*****                                                                  00920379
                     96: C*****    HEADER FOR SEGMENT 201                                        00930379
                     97:         WRITE(NUVI,20101)                                               00940379
                     98: 20101   FORMAT(1H , / 35H  XRFOR - (201) INTRINSIC FUNCTIONS//          00950379
                     99:      1         24H  TRIGONOMETRIC FORMULAE//                            00960379
                    100:      2         20H  SUBSET REF. - 15.3)                                 00970379
                    101: CBB** ********************** BBCHED0B **********************************00980379
                    102: C**** WRITE DETAIL REPORT HEADERS                                       00990379
                    103: C****                                                                   01000379
                    104:       WRITE (I02,90004)                                                 01010379
                    105:       WRITE (I02,90004)                                                 01020379
                    106:       WRITE (I02,90013)                                                 01030379
                    107:       WRITE (I02,90014)                                                 01040379
                    108:       WRITE (I02,90015) IVTOTL                                          01050379
                    109: CBE** ********************** BBCHED0B **********************************01060379
                    110: C*****                                                                  01070379
                    111:         PIVS = 3.1415926535897932384626434                              01080379
                    112: C*****                                                                  01090379
                    113: CT001*  TEST 1                                           LN(EXP(X)) = 1 01100379
                    114:            IVTNUM = 1                                                   01110379
                    115:         BVS = 17.5                                                      01120379
                    116:         AVS = ALOG(EXP(1.75)) - BVS / 10.0                              01130379
                    117:            IF (AVS + 0.50000E-04) 20010, 10010, 40010                   01140379
                    118: 40010      IF (AVS - 0.50000E-04) 10010, 10010, 20010                   01150379
                    119: 10010      IVPASS = IVPASS + 1                                          01160379
                    120:            WRITE (NUVI, 80002) IVTNUM                                   01170379
                    121:            GO TO 0011                                                   01180379
                    122: 20010      IVFAIL = IVFAIL + 1                                          01190379
                    123:            RVCORR = 0.0000                                              01200379
                    124:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      01210379
                    125:  0011      CONTINUE                                                     01220379
                    126: CT002*  TEST 2                                      SIN**2 + COS**2 = 1 01230379
                    127:            IVTNUM = 2                                                   01240379
                    128:         BVS = 10.0 / 4.0                                                01250379
                    129:         CVS = SIN(BVS) ** 2                                             01260379
                    130:         DVS = COS(BVS) ** 2                                             01270379
                    131:         AVS = CVS + DVS - 1.0                                           01280379
                    132:            IF (AVS + 0.50000E-04) 20020, 10020, 40020                   01290379
                    133: 40020      IF (AVS - 0.50000E-04) 10020, 10020, 20020                   01300379
                    134: 10020      IVPASS = IVPASS + 1                                          01310379
                    135:            WRITE (NUVI, 80002) IVTNUM                                   01320379
                    136:            GO TO 0021                                                   01330379
                    137: 20020      IVFAIL = IVFAIL + 1                                          01340379
                    138:            RVCORR = 0.0000                                              01350379
                    139:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      01360379
                    140:  0021      CONTINUE                                                     01370379
                    141: CT003*  TEST 3                                SIN(2X) = 2*SIN(X)*COS(X) 01380379
                    142:            IVTNUM = 3                                                   01390379
                    143:         BVS = 8.5                                                       01400379
                    144:         CVS = BVS * (-0.5)                                              01410379
                    145:         AVS = (SIN(-4.25) * COS(CVS)) * 2.0 - SIN(-8.5)                 01420379
                    146:            IF (AVS + 0.50000E-04) 20030, 10030, 40030                   01430379
                    147: 40030      IF (AVS - 0.50000E-04) 10030, 10030, 20030                   01440379
                    148: 10030      IVPASS = IVPASS + 1                                          01450379
                    149:            WRITE (NUVI, 80002) IVTNUM                                   01460379
                    150:            GO TO 0031                                                   01470379
                    151: 20030      IVFAIL = IVFAIL + 1                                          01480379
                    152:            RVCORR = 0.0000                                              01490379
                    153:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      01500379
                    154:  0031      CONTINUE                                                     01510379
                    155: CT004*  TEST 4                               ARCSIN(X) = ARCCOS(1-X**2) 01520379
                    156:            IVTNUM = 4                                                   01530379
                    157:         AVS = ASIN(-0.875) + ACOS(SQRT(1.0 - (0.875)  ** 2))            01540379
                    158:            IF (AVS + 0.50000E-04) 20040, 10040, 40040                   01550379
                    159: 40040      IF (AVS - 0.50000E-04) 10040, 10040, 20040                   01560379
                    160: 10040      IVPASS = IVPASS + 1                                          01570379
                    161:            WRITE (NUVI, 80002) IVTNUM                                   01580379
                    162:            GO TO 0041                                                   01590379
                    163: 20040      IVFAIL = IVFAIL + 1                                          01600379
                    164:            RVCORR = 0.0000                                              01610379
                    165:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      01620379
                    166:  0041      CONTINUE                                                     01630379
                    167: CT005*  TEST 5                       TAN(X)**2 - 1 = -COS(2X)/COS(X)**2 01640379
                    168:            IVTNUM = 5                                                   01650379
                    169:         BVS = 7.0                                                       01660379
                    170:         AVS = COS(1.75) / COS(BVS / 8.0) ** 2 + TAN(0.875) ** 2 -       01670379
                    171:      1            1                                                     01680379
                    172:            IF (AVS + 0.50000E-04) 20050, 10050, 40050                   01690379
                    173: 40050      IF (AVS - 0.50000E-04) 10050, 10050, 20050                   01700379
                    174: 10050      IVPASS = IVPASS + 1                                          01710379
                    175:            WRITE (NUVI, 80002) IVTNUM                                   01720379
                    176:            GO TO 0051                                                   01730379
                    177: 20050      IVFAIL = IVFAIL + 1                                          01740379
                    178:            RVCORR = 0.0000                                              01750379
                    179:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      01760379
                    180:  0051      CONTINUE                                                     01770379
                    181: CT006*  TEST 6                           ATAN(X/Y) = ATAN2(X,Y),  Y > 0 01780379
                    182:            IVTNUM = 6                                                   01790379
                    183:         BVS = 12.0                                                      01800379
                    184:         CVS = ATAN2(BVS / 4.0, BVS / 3.0)                               01810379
                    185:         AVS = CVS - ATAN(0.75)                                          01820379
                    186:            IF (AVS + 0.50000E-04) 20060, 10060, 40060                   01830379
                    187: 40060      IF (AVS - 0.50000E-04) 10060, 10060, 20060                   01840379
                    188: 10060      IVPASS = IVPASS + 1                                          01850379
                    189:            WRITE (NUVI, 80002) IVTNUM                                   01860379
                    190:            GO TO 0061                                                   01870379
                    191: 20060      IVFAIL = IVFAIL + 1                                          01880379
                    192:            RVCORR = 0.0000                                              01890379
                    193:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      01900379
                    194:  0061      CONTINUE                                                     01910379
                    195: CT007*  TEST 7                                           SQRT(X)**2 = X 01920379
                    196:            IVTNUM = 7                                                   01930379
                    197:         AVS = SQRT(9.125) ** 2 - 9.125                                  01940379
                    198:            IF (AVS + 0.50000E-04) 20070, 10070, 40070                   01950379
                    199: 40070      IF (AVS - 0.50000E-04) 10070, 10070, 20070                   01960379
                    200: 10070      IVPASS = IVPASS + 1                                          01970379
                    201:            WRITE (NUVI, 80002) IVTNUM                                   01980379
                    202:            GO TO 0071                                                   01990379
                    203: 20070      IVFAIL = IVFAIL + 1                                          02000379
                    204:            RVCORR = 0.0000                                              02010379
                    205:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      02020379
                    206:  0071      CONTINUE                                                     02030379
                    207: CT008*  TEST 8                                LN(X) = LN(10) * LOG10(X) 02040379
                    208:            IVTNUM = 8                                                   02050379
                    209:         BVS = 62.5 / 1000.0                                             02060379
                    210:         AVS = ALOG10(BVS) * ALOG(10.0) - ALOG(0.0625)                   02070379
                    211:            IF (AVS + 0.50000E-04) 20080, 10080, 40080                   02080379
                    212: 40080      IF (AVS - 0.50000E-04) 10080, 10080, 20080                   02090379
                    213: 10080      IVPASS = IVPASS + 1                                          02100379
                    214:            WRITE (NUVI, 80002) IVTNUM                                   02110379
                    215:            GO TO 0081                                                   02120379
                    216: 20080      IVFAIL = IVFAIL + 1                                          02130379
                    217:            RVCORR = 0.0000                                              02140379
                    218:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      02150379
                    219:  0081      CONTINUE                                                     02160379
                    220: CT009*  TEST 9                                    COSH**2 - SINH**2 = 1 02170379
                    221:            IVTNUM = 9                                                   02180379
                    222:         BVS = 0.125                                                     02190379
                    223:         CVS = SINH(2.125)                                               02200379
                    224:         DVS = COSH(2.0 + BVS)                                           02210379
                    225:         AVS = DVS  ** 2 - CVS ** 2 - COSH(0.0)                          02220379
                    226:            IF (AVS + 0.50000E-04) 20090, 10090, 40090                   02230379
                    227: 40090      IF (AVS - 0.50000E-04) 10090, 10090, 20090                   02240379
                    228: 10090      IVPASS = IVPASS + 1                                          02250379
                    229:            WRITE (NUVI, 80002) IVTNUM                                   02260379
                    230:            GO TO 0091                                                   02270379
                    231: 20090      IVFAIL = IVFAIL + 1                                          02280379
                    232:            RVCORR = 0.0000                                              02290379
                    233:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      02300379
                    234:  0091      CONTINUE                                                     02310379
                    235: CT010*  TEST 10                             TANH(X) = 1 - 2/(EXP(2X)+1) 02320379
                    236:            IVTNUM = 10                                                  02330379
                    237:         BVS = 5.0                                                       02340379
                    238:         CVS = 2.0                                                       02350379
                    239:         DVS = ALOG10(BVS * CVS) - SQRT(4.0) /                           02360379
                    240:      1  (EXP(2.0 * (BVS - CVS)) + COS(0.0))                             02370379
                    241:         AVS = DVS - TANH(3.0)                                           02380379
                    242:            IF (AVS + 0.50000E-04) 20100, 10100, 40100                   02390379
                    243: 40100      IF (AVS - 0.50000E-04) 10100, 10100, 20100                   02400379
                    244: 10100      IVPASS = IVPASS + 1                                          02410379
                    245:            WRITE (NUVI, 80002) IVTNUM                                   02420379
                    246:            GO TO 0101                                                   02430379
                    247: 20100      IVFAIL = IVFAIL + 1                                          02440379
                    248:            RVCORR = 0.0000                                              02450379
                    249:            WRITE (NUVI, 80012) IVTNUM, AVS, RVCORR                      02460379
                    250:  0101      CONTINUE                                                     02470379
                    251: C*****                                                                  02480379
                    252: CBB** ********************** BBCSUM0  **********************************02490379
                    253: C**** WRITE OUT TEST SUMMARY                                            02500379
                    254: C****                                                                   02510379
                    255:       IVTOTN = IVPASS + IVFAIL + IVDELE + IVINSP                        02520379
                    256:       WRITE (I02, 90004)                                                02530379
                    257:       WRITE (I02, 90014)                                                02540379
                    258:       WRITE (I02, 90004)                                                02550379
                    259:       WRITE (I02, 90020) IVPASS                                         02560379
                    260:       WRITE (I02, 90022) IVFAIL                                         02570379
                    261:       WRITE (I02, 90024) IVDELE                                         02580379
                    262:       WRITE (I02, 90026) IVINSP                                         02590379
                    263:       WRITE (I02, 90028) IVTOTN, IVTOTL                                 02600379
                    264: CBE** ********************** BBCSUM0  **********************************02610379
                    265: CBB** ********************** BBCFOOT0 **********************************02620379
                    266: C**** WRITE OUT REPORT FOOTINGS                                         02630379
                    267: C****                                                                   02640379
                    268:       WRITE (I02,90016) ZPROG, ZPROG                                    02650379
                    269:       WRITE (I02,90018) ZPROJ, ZNAME, ZTAPE, ZTAPED                     02660379
                    270:       WRITE (I02,90019)                                                 02670379
                    271: CBE** ********************** BBCFOOT0 **********************************02680379
                    272: CBB** ********************** BBCFMT0A **********************************02690379
                    273: C**** FORMATS FOR TEST DETAIL LINES                                     02700379
                    274: C****                                                                   02710379
                    275: 80000 FORMAT (1H ,2X,I3,4X,7HDELETED,32X,A31)                           02720379
                    276: 80002 FORMAT (1H ,2X,I3,4X,7H PASS  ,32X,A31)                           02730379
                    277: 80004 FORMAT (1H ,2X,I3,4X,7HINSPECT,32X,A31)                           02740379
                    278: 80008 FORMAT (1H ,2X,I3,4X,7H FAIL  ,32X,A31)                           02750379
                    279: 80010 FORMAT (1H ,2X,I3,4X,7H FAIL  ,/,1H ,15X,10HCOMPUTED= ,           02760379
                    280:      1I6,/,1H ,15X,10HCORRECT=  ,I6)                                    02770379
                    281: 80012 FORMAT (1H ,2X,I3,4X,7H FAIL  ,/,1H ,16X,10HCOMPUTED= ,           02780379
                    282:      1E12.5,/,1H ,16X,10HCORRECT=  ,E12.5)                              02790379
                    283: 80018 FORMAT (1H ,2X,I3,4X,7H FAIL  ,/,1H ,16X,10HCOMPUTED= ,           02800379
                    284:      1A21,/,1H ,16X,10HCORRECT=  ,A21)                                  02810379
                    285: 80020 FORMAT (1H ,16X,10HCOMPUTED= ,A21,1X,A31)                         02820379
                    286: 80022 FORMAT (1H ,16X,10HCORRECT=  ,A21,1X,A31)                         02830379
                    287: 80024 FORMAT (1H ,16X,10HCOMPUTED= ,I6,16X,A31)                         02840379
                    288: 80026 FORMAT (1H ,16X,10HCORRECT=  ,I6,16X,A31)                         02850379
                    289: 80028 FORMAT (1H ,16X,10HCOMPUTED= ,E12.5,10X,A31)                      02860379
                    290: 80030 FORMAT (1H ,16X,10HCORRECT=  ,E12.5,10X,A31)                      02870379
                    291: 80050 FORMAT (1H ,48X,A31)                                              02880379
                    292: CBE** ********************** BBCFMT0A **********************************02890379
                    293: CBB** ********************** BBCFMT0B **********************************02900379
                    294: C**** FORMAT STATEMENTS FOR PAGE HEADERS                                02910379
                    295: C****                                                                   02920379
                    296: 90002 FORMAT (1H1)                                                      02930379
                    297: 90004 FORMAT (1H )                                                      02940379
                    298: 90006 FORMAT (1H ,20X,31HFEDERAL SOFTWARE TESTING CENTER)               02950379
                    299: 90007 FORMAT (1H ,19X,34HFORTRAN COMPILER VALIDATION SYSTEM)            02960379
                    300: 90008 FORMAT (1H ,21X,A13,A17)                                          02970379
                    301: 90009 FORMAT (1H ,/,2H *,A5,6HBEGIN*,12X,15HTEST RESULTS - ,A5,/)       02980379
                    302: 90010 FORMAT (1H ,8X,16HTEST DATE*TIME= ,A17,15H  -  COMPILER= ,A20)    02990379
                    303: 90013 FORMAT (1H ,8H TEST   ,10HPASS/FAIL ,6X,17HDISPLAYED RESULTS,     03000379
                    304:      1       7X,7HREMARKS,24X)                                          03010379
                    305: 90014 FORMAT (1H ,46H----------------------------------------------,    03020379
                    306:      1        33H---------------------------------)                     03030379
                    307: 90015 FORMAT (1H ,48X,17HTHIS PROGRAM HAS ,I3,6H TESTS,/)               03040379
                    308: C****                                                                   03050379
                    309: C**** FORMAT STATEMENTS FOR REPORT FOOTINGS                             03060379
                    310: C****                                                                   03070379
                    311: 90016 FORMAT (1H ,/,2H *,A5,4HEND*,14X,14HEND OF TEST - ,A5,/)          03080379
                    312: 90018 FORMAT (1H ,A13,13X,A20,7H   *   ,A10,1H/,                        03090379
                    313:      1        A13)                                                      03100379
                    314: 90019 FORMAT (1H ,26HFOR OFFICIAL USE ONLY     ,35X,15HCOPYRIGHT  1982) 03110379
                    315: C****                                                                   03120379
                    316: C**** FORMAT STATEMENTS FOR RUN SUMMARY                                 03130379
                    317: C****                                                                   03140379
                    318: 90020 FORMAT (1H ,21X,I5,13H TESTS PASSED)                              03150379
                    319: 90022 FORMAT (1H ,21X,I5,13H TESTS FAILED)                              03160379
                    320: 90024 FORMAT (1H ,21X,I5,14H TESTS DELETED)                             03170379
                    321: 90026 FORMAT (1H ,21X,I5,25H TESTS REQUIRE INSPECTION)                  03180379
                    322: 90028 FORMAT (1H ,21X,I5,4H OF ,I3,15H TESTS EXECUTED)                  03190379
                    323: CBE** ********************** BBCFMT0B **********************************03200379
                    324: C*****                                                                  03210379
                    325: C*****    END OF TEST SEGMENT 201                                       03220379
                    326:       STOP                                                              03230379
                    327:       END                                                               03240379
                    328:                                                                         03250379

unix.superglobalmegacorp.com

This archive runs on limited infrastructure. Preserving old code on modern bandwidth. Automated agents are requested to crawl responsibly.