Annotation of cci/usr/src/usr.bin/f77/testf77/tests/FM816.f, revision 1.1

1.1     ! root        1: C***********************************************************************00010816
        !             2: C     DATE***82/08/02*18.33.46
        !             3: C     OWNER  PRE/850703/TC-85-   -410/    /FSTC/278FCVS*F78UBP20/
        !             4: C     AUDIT  FCVS78 V2.0
        !             5: C*****  FORTRAN 77                                                      00020816
        !             6: C*****   FM816                                                          00030816
        !             7: C*****                       YDLOG - (182)                              00040816
        !             8: C*****                                                                  00050816
        !             9: C***********************************************************************00060816
        !            10: C*****  GENERAL PURPOSE                                         ANS REF 00070816
        !            11: C*****    TEST INTRINSIC FUNCTION DLOG                           15.3   00080816
        !            12: C*****                                                          TABLE 5 00090816
        !            13: CBB** ********************** BBCCOMNT **********************************00100816
        !            14: C****                                                                   00110816
        !            15: C****            1978 FORTRAN COMPILER VALIDATION SYSTEM                00120816
        !            16: C****                          VERSION 2.0                              00130816
        !            17: C****                                                                   00140816
        !            18: C****                                                                   00150816
        !            19: C****           SUGGESTIONS AND COMMENTS SHOULD BE FORWARDED TO         00160816
        !            20: C****                   GENERAL SERVICES ADMINISTRATION                 00170816
        !            21: C****                   FEDERAL SOFTWARE TESTING CENTER                 00180816
        !            22: C****                   5203 LEESBURG PIKE, SUITE 1100                  00190816
        !            23: C****                      FALLS CHURCH, VA. 22041                      00200816
        !            24: C****                                                                   00210816
        !            25: C****                          (703) 756-6153                           00220816
        !            26: C****                                                                   00230816
        !            27: CBE** ********************** BBCCOMNT **********************************00240816
        !            28: C*****                                                                  00250816
        !            29: C*****  S P E C I F I C A T I O N S  SEGMENT 182                        00260816
        !            30:         DOUBLE PRECISION AVD, BVD, CVD, DVCORR                          00270816
        !            31: C*****                                                                  00280816
        !            32: CBB** ********************** BBCINITA **********************************00290816
        !            33: C**** SPECIFICATION STATEMENTS                                          00300816
        !            34: C****                                                                   00310816
        !            35:       CHARACTER ZVERS*13, ZVERSD*17, ZDATE*17, ZPROG*5, ZCOMPL*20,      00320816
        !            36:      1          ZNAME*20, ZTAPE*10, ZPROJ*13, REMRKS*31, ZTAPED*13      00330816
        !            37: CBE** ********************** BBCINITA **********************************00340816
        !            38: CBB** ********************** BBCINITB **********************************00350816
        !            39: C**** INITIALIZE SECTION                                                00360816
        !            40:       DATA  ZVERS,                  ZVERSD,             ZDATE           00370816
        !            41:      1      /'VERSION 2.0  ',  '82/08/02*18.33.46',  '*NO DATE*TIME'/   00380816
        !            42:       DATA       ZCOMPL,             ZNAME,             ZTAPE           00390816
        !            43:      1      /'*NONE SPECIFIED*', '*NO COMPANY NAME*', '*NO TAPE*'/      00400816
        !            44:       DATA       ZPROJ,           ZTAPED,         ZPROG                 00410816
        !            45:      1      /'*NO PROJECT*',   '*NO TAPE DATE',  'XXXXX'/               00420816
        !            46:       DATA   REMRKS /'                               '/                 00430816
        !            47: C**** THE FOLLOWING 9 COMMENT LINES (CZ01, CZ02, ...) CAN BE REPLACED   00440816
        !            48: C**** FOR IDENTIFYING THE TEST ENVIRONMENT                              00450816
        !            49: C****                                                                   00460816
        !            50: CZ01  ZVERS  = 'VERSION OF THE COMPILER VALIDATION SYSTEM'              00470816
        !            51: CZ02  ZVERSD = 'CREATION DATE/TIME OF THE COMPILER VALIDATION SYSTEM'   00480816
        !            52: CZ03  ZPROG  = 'PROGRAM NAME'                                           00490816
        !            53:       ZDATE  = '07-Nov-85        '                                           *RP
        !            54:       ZCOMPL = 'CCI 5.2             '                                        *RP
        !            55:       ZPROJ  = 'TC-85-   -410'                                               *RP
        !            56:       ZNAME  = '                    '                                        *RP
        !            57:       ZTAPE  = '          '                                                  *RP
        !            58:       ZTAPED = '850703       '                                               *RP
        !            59: C                                                                       00560816
        !            60:       IVPASS = 0                                                        00570816
        !            61:       IVFAIL = 0                                                        00580816
        !            62:       IVDELE = 0                                                        00590816
        !            63:       IVINSP = 0                                                        00600816
        !            64:       IVTOTL = 0                                                        00610816
        !            65:       IVTOTN = 0                                                        00620816
        !            66:       ICZERO = 0                                                        00630816
        !            67: C                                                                       00640816
        !            68: C     I01 CONTAINS THE LOGICAL UNIT NUMBER FOR THE CARD READER.         00650816
        !            69:       I01 = 05                                                          00660816
        !            70: C     I02 CONTAINS THE LOGICAL UNIT NUMBER FOR THE PRINTER.             00670816
        !            71:       I02 = 06                                                          00680816
        !            72: C                                                                       00690816
        !            73:       I01 = 5                                                           00700816
        !            74: C     THE CX010 CARD IS FOR OVERRIDING THE PROGRAM DEFAULT I01 = 5      00710816
        !            75: CX011   REPLACED BY FEXEC X-011 CONTROL CARD.  CX011 IS FOR SYSTEMS     00720816
        !            76: C     REQUIRING ADDITIONAL STATEMENTS FOR FILES ASSOCIATED WITH CX010.  00730816
        !            77: C                                                                       00740816
        !            78:       I02 = 6                                                           00750816
        !            79: C     THE CX020 CARD IS FOR OVERRIDING THE PROGRAM DEFAULT I02= 6       00760816
        !            80: CX021   REPLACED BY FEXEC X-021 CONTROL CARD.  CX021 IS FOR SYSTEMS     00770816
        !            81: C     REQUIRING ADDITIONAL STATEMENTS FOR FILES ASSOCIATED WITH CX020.  00780816
        !            82: C                                                                       00790816
        !            83: CBE** ********************** BBCINITB **********************************00800816
        !            84:       NUVI = I02                                                        00810816
        !            85:       IVTOTL = 16                                                       00820816
        !            86:       ZPROG = 'FM816'                                                   00830816
        !            87: CBB** ********************** BBCHED0A **********************************00840816
        !            88: C****                                                                   00850816
        !            89: C**** WRITE REPORT TITLE                                                00860816
        !            90: C****                                                                   00870816
        !            91:       WRITE (I02, 90002)                                                00880816
        !            92:       WRITE (I02, 90006)                                                00890816
        !            93:       WRITE (I02, 90007)                                                00900816
        !            94:       WRITE (I02, 90008)  ZVERS, ZVERSD                                 00910816
        !            95:       WRITE (I02, 90009)  ZPROG, ZPROG                                  00920816
        !            96:       WRITE (I02, 90010)  ZDATE, ZCOMPL                                 00930816
        !            97: CBE** ********************** BBCHED0A **********************************00940816
        !            98: C*****                                                                  00950816
        !            99: C*****    HEADER FOR SEGMENT 182                                        00960816
        !           100:         WRITE(NUVI,18200)                                               00970816
        !           101: 18200   FORMAT(1H , / 35H  YDLOG - (182) INTRINSIC FUNCTIONS//          00980816
        !           102:      1         43H  DLOG (DOUBLE PRECISION NATURAL LOGARITHM)//         00990816
        !           103:      2         17H  ANS REF. - 15.3)                                    01000816
        !           104: CBB** ********************** BBCHED0B **********************************01010816
        !           105: C**** WRITE DETAIL REPORT HEADERS                                       01020816
        !           106: C****                                                                   01030816
        !           107:       WRITE (I02,90004)                                                 01040816
        !           108:       WRITE (I02,90004)                                                 01050816
        !           109:       WRITE (I02,90013)                                                 01060816
        !           110:       WRITE (I02,90014)                                                 01070816
        !           111:       WRITE (I02,90015) IVTOTL                                          01080816
        !           112: CBE** ********************** BBCHED0B **********************************01090816
        !           113: C*****                                                                  01100816
        !           114: CT001*  TEST 1                               ONE, SINCE LN(1.0) = 0.0   01110816
        !           115:            IVTNUM = 1                                                   01120816
        !           116:         BVD = 1.0D0                                                     01130816
        !           117:         AVD = DLOG(BVD)                                                 01140816
        !           118:            IF (AVD + 0.5000000000D-09) 20010, 10010, 40010              01150816
        !           119: 40010      IF (AVD - 0.5000000000D-09) 10010, 10010, 20010              01160816
        !           120: 10010      IVPASS = IVPASS + 1                                          01170816
        !           121:            WRITE (NUVI, 80002) IVTNUM                                   01180816
        !           122:            GO TO 0011                                                   01190816
        !           123: 20010      IVFAIL = IVFAIL + 1                                          01200816
        !           124:            DVCORR = 0.00000000000000000000D+00                          01210816
        !           125:            WRITE (NUVI, 80031) IVTNUM, AVD, DVCORR                      01220816
        !           126:  0011      CONTINUE                                                     01230816
        !           127: CT002*  TEST 2                                       VALUE CLOSE TO E   01240816
        !           128:            IVTNUM = 2                                                   01250816
        !           129:         AVD = DLOG(2.6875D0)                                            01260816
        !           130:            IF (AVD - 0.9886113929D+00) 20020, 10020, 40020              01270816
        !           131: 40020      IF (AVD - 0.9886113940D+00) 10020, 10020, 20020              01280816
        !           132: 10020      IVPASS = IVPASS + 1                                          01290816
        !           133:            WRITE (NUVI, 80002) IVTNUM                                   01300816
        !           134:            GO TO 0021                                                   01310816
        !           135: 20020      IVFAIL = IVFAIL + 1                                          01320816
        !           136:            DVCORR = 0.98861139345378118580D+00                          01330816
        !           137:            WRITE (NUVI, 80031) IVTNUM, AVD, DVCORR                      01340816
        !           138:  0021      CONTINUE                                                     01350816
        !           139: CT003*  TEST 3                                                          01360816
        !           140:            IVTNUM = 3                                                   01370816
        !           141:         AVD = DLOG(5.125D0)                                             01380816
        !           142:            IF (AVD - 0.1634130524D+01) 20030, 10030, 40030              01390816
        !           143: 40030      IF (AVD - 0.1634130526D+01) 10030, 10030, 20030              01400816
        !           144: 10030      IVPASS = IVPASS + 1                                          01410816
        !           145:            WRITE (NUVI, 80002) IVTNUM                                   01420816
        !           146:            GO TO 0031                                                   01430816
        !           147: 20030      IVFAIL = IVFAIL + 1                                          01440816
        !           148:            DVCORR = 1.6341305250244718756D+00                           01450816
        !           149:            WRITE (NUVI, 80031) IVTNUM, AVD, DVCORR                      01460816
        !           150:  0031      CONTINUE                                                     01470816
        !           151: CT004*  TEST 4                                                          01480816
        !           152:            IVTNUM = 4                                                   01490816
        !           153:         AVD = DLOG(10.0D0)                                              01500816
        !           154:            IF (AVD - 0.2302585091D+01) 20040, 10040, 40040              01510816
        !           155: 40040      IF (AVD - 0.2302585095D+01) 10040, 10040, 20040              01520816
        !           156: 10040      IVPASS = IVPASS + 1                                          01530816
        !           157:            WRITE (NUVI, 80002) IVTNUM                                   01540816
        !           158:            GO TO 0041                                                   01550816
        !           159: 20040      IVFAIL = IVFAIL + 1                                          01560816
        !           160:            DVCORR = 2.3025850929940456840D+00                           01570816
        !           161:            WRITE (NUVI, 80031) IVTNUM, AVD, DVCORR                      01580816
        !           162:  0041      CONTINUE                                                     01590816
        !           163: CT005*  TEST 5                                                          01600816
        !           164:            IVTNUM = 5                                                   01610816
        !           165:         AVD = DLOG(100.0D0)                                             01620816
        !           166:            IF (AVD - 0.4605170183D+01) 20050, 10050, 40050              01630816
        !           167: 40050      IF (AVD - 0.4605170189D+01) 10050, 10050, 20050              01640816
        !           168: 10050      IVPASS = IVPASS + 1                                          01650816
        !           169:            WRITE (NUVI, 80002) IVTNUM                                   01660816
        !           170:            GO TO 0051                                                   01670816
        !           171: 20050      IVFAIL = IVFAIL + 1                                          01680816
        !           172:            DVCORR = 4.6051701859880913680D+00                           01690816
        !           173:            WRITE (NUVI, 80031) IVTNUM, AVD, DVCORR                      01700816
        !           174:  0051      CONTINUE                                                     01710816
        !           175: CT006*  TEST 6                                                          01720816
        !           176:            IVTNUM = 6                                                   01730816
        !           177:         BVD = 1.0D0                                                     01740816
        !           178:         AVD = DLOG(BVD / 4.D0)                                          01750816
        !           179:            IF (AVD + 0.1386294362D+01) 20060, 10060, 40060              01760816
        !           180: 40060      IF (AVD + 0.1386294360D+01) 10060, 10060, 20060              01770816
        !           181: 10060      IVPASS = IVPASS + 1                                          01780816
        !           182:            WRITE (NUVI, 80002) IVTNUM                                   01790816
        !           183:            GO TO 0061                                                   01800816
        !           184: 20060      IVFAIL = IVFAIL + 1                                          01810816
        !           185:            DVCORR = -1.3862943611198906188D+00                          01820816
        !           186:            WRITE (NUVI, 80031) IVTNUM, AVD, DVCORR                      01830816
        !           187:  0061      CONTINUE                                                     01840816
        !           188: CT007*  TEST 7                                                          01850816
        !           189:            IVTNUM = 7                                                   01860816
        !           190:         BVD = 1.0D0                                                     01870816
        !           191:         CVD = 8.0D0                                                     01880816
        !           192:         AVD = DLOG(3.0D0 * BVD / CVD)                                   01890816
        !           193:            IF (AVD + 0.9808292535D+00) 20070, 10070, 40070              01900816
        !           194: 40070      IF (AVD + 0.9808292525D+00) 10070, 10070, 20070              01910816
        !           195: 10070      IVPASS = IVPASS + 1                                          01920816
        !           196:            WRITE (NUVI, 80002) IVTNUM                                   01930816
        !           197:            GO TO 0071                                                   01940816
        !           198: 20070      IVFAIL = IVFAIL + 1                                          01950816
        !           199:            DVCORR = -0.98082925301172623686D+00                         01960816
        !           200:            WRITE (NUVI, 80031) IVTNUM, AVD, DVCORR                      01970816
        !           201:  0071      CONTINUE                                                     01980816
        !           202: CT008*  TEST 8                                                          01990816
        !           203:            IVTNUM = 8                                                   02000816
        !           204:         AVD = DLOG(50.0D0 / 100.0D0)                                    02010816
        !           205:            IF (AVD + 0.6931471809D+00) 20080, 10080, 40080              02020816
        !           206: 40080      IF (AVD + 0.6931471802D+00) 10080, 10080, 20080              02030816
        !           207: 10080      IVPASS = IVPASS + 1                                          02040816
        !           208:            WRITE (NUVI, 80002) IVTNUM                                   02050816
        !           209:            GO TO 0081                                                   02060816
        !           210: 20080      IVFAIL = IVFAIL + 1                                          02070816
        !           211:            DVCORR = -0.69314718055994530942D+00                         02080816
        !           212:            WRITE (NUVI, 80031) IVTNUM, AVD, DVCORR                      02090816
        !           213:  0081      CONTINUE                                                     02100816
        !           214: CT009*  TEST 9                                                          02110816
        !           215:            IVTNUM = 9                                                   02120816
        !           216:         BVD = 68.75D0                                                   02130816
        !           217:         AVD = DLOG(BVD * 0.01D0)                                        02140816
        !           218:            IF (AVD + 0.3746934497D+00) 20090, 10090, 40090              02150816
        !           219: 40090      IF (AVD + 0.3746934492D+00) 10090, 10090, 20090              02160816
        !           220: 10090      IVPASS = IVPASS + 1                                          02170816
        !           221:            WRITE (NUVI, 80002) IVTNUM                                   02180816
        !           222:            GO TO 0091                                                   02190816
        !           223: 20090      IVFAIL = IVFAIL + 1                                          02200816
        !           224:            DVCORR = -0.37469344944141069361D+00                         02210816
        !           225:            WRITE (NUVI, 80031) IVTNUM, AVD, DVCORR                      02220816
        !           226:  0091      CONTINUE                                                     02230816
        !           227: CT010*  TEST 10                                   VALUES CLOSE TO ONE   02240816
        !           228:            IVTNUM = 10                                                  02250816
        !           229:         AVD = DLOG(0.96875D0)                                           02260816
        !           230:            IF (AVD + 0.3174869833D-01) 20100, 10100, 40100              02270816
        !           231: 40100      IF (AVD + 0.3174869829D-01) 10100, 10100, 20100              02280816
        !           232: 10100      IVPASS = IVPASS + 1                                          02290816
        !           233:            WRITE (NUVI, 80002) IVTNUM                                   02300816
        !           234:            GO TO 0101                                                   02310816
        !           235: 20100      IVFAIL = IVFAIL + 1                                          02320816
        !           236:            DVCORR = -0.031748698314580301157D+00                        02330816
        !           237:            WRITE (NUVI, 80031) IVTNUM, AVD, DVCORR                      02340816
        !           238:  0101      CONTINUE                                                     02350816
        !           239: CT011*  TEST 11                                                         02360816
        !           240:            IVTNUM = 11                                                  02370816
        !           241:         BVD = 1.015625D0                                                02380816
        !           242:         AVD = DLOG(BVD)                                                 02390816
        !           243:            IF (AVD - 0.1550418652D-01) 20110, 10110, 40110              02400816
        !           244: 40110      IF (AVD - 0.1550418655D-01) 10110, 10110, 20110              02410816
        !           245: 10110      IVPASS = IVPASS + 1                                          02420816
        !           246:            WRITE (NUVI, 80002) IVTNUM                                   02430816
        !           247:            GO TO 0111                                                   02440816
        !           248: 20110      IVFAIL = IVFAIL + 1                                          02450816
        !           249:            DVCORR = 0.015504186535965254150D+00                         02460816
        !           250:            WRITE (NUVI, 80031) IVTNUM, AVD, DVCORR                      02470816
        !           251:  0111      CONTINUE                                                     02480816
        !           252: CT012*  TEST 12                                  VALUES CLOSE TO ZERO   02490816
        !           253:            IVTNUM = 12                                                  02500816
        !           254:         BVD = 128.0D0                                                   02510816
        !           255:         AVD = DLOG(1.0D0 / BVD)                                         02520816
        !           256:            IF (AVD + 0.4852030267D+01) 20120, 10120, 40120              02530816
        !           257: 40120      IF (AVD + 0.4852030261D+01) 10120, 10120, 20120              02540816
        !           258: 10120      IVPASS = IVPASS + 1                                          02550816
        !           259:            WRITE (NUVI, 80002) IVTNUM                                   02560816
        !           260:            GO TO 0121                                                   02570816
        !           261: 20120      IVFAIL = IVFAIL + 1                                          02580816
        !           262:            DVCORR = -4.8520302639196171659D+00                          02590816
        !           263:            WRITE (NUVI, 80031) IVTNUM, AVD, DVCORR                      02600816
        !           264:  0121      CONTINUE                                                     02610816
        !           265: CT013*  TEST 13                                                         02620816
        !           266:            IVTNUM = 13                                                  02630816
        !           267:         BVD = 128.0D0                                                   02640816
        !           268:         AVD = DLOG(1.0D0 / (BVD * 4.0D0))                               02650816
        !           269:            IF (AVD + 0.6238324629D+01) 20130, 10130, 40130              02660816
        !           270: 40130      IF (AVD + 0.6238324622D+01) 10130, 10130, 20130              02670816
        !           271: 10130      IVPASS = IVPASS + 1                                          02680816
        !           272:            WRITE (NUVI, 80002) IVTNUM                                   02690816
        !           273:            GO TO 0131                                                   02700816
        !           274: 20130      IVFAIL = IVFAIL + 1                                          02710816
        !           275:            DVCORR = -6.2383246250395077848D+00                          02720816
        !           276:            WRITE (NUVI, 80031) IVTNUM, AVD, DVCORR                      02730816
        !           277:  0131      CONTINUE                                                     02740816
        !           278: CT014*  TEST 14                         AN ARGUMENT OF HIGH MAGNITUDE   02750816
        !           279:            IVTNUM = 14                                                  02760816
        !           280:         BVD = 1.0D+37                                                   02770816
        !           281:         AVD = DLOG(BVD)                                                 02780816
        !           282:            IF (AVD - 0.8519564839D+02) 20140, 10140, 40140              02790816
        !           283: 40140      IF (AVD - 0.8519564849D+02) 10140, 10140, 20140              02800816
        !           284: 10140      IVPASS = IVPASS + 1                                          02810816
        !           285:            WRITE (NUVI, 80002) IVTNUM                                   02820816
        !           286:            GO TO 0141                                                   02830816
        !           287: 20140      IVFAIL = IVFAIL + 1                                          02840816
        !           288:            DVCORR = 85.195648440779690309D+00                           02850816
        !           289:            WRITE (NUVI, 80031) IVTNUM, AVD, DVCORR                      02860816
        !           290:  0141      CONTINUE                                                     02870816
        !           291: CT015*  TEST 15                          AN ARGUMENT OF LOW MAGNITUDE   02880816
        !           292:            IVTNUM = 15                                                  02890816
        !           293:         BVD = 1.0D-37                                                   02900816
        !           294:         AVD = DLOG(BVD)                                                 02910816
        !           295:            IF (AVD + 0.8519564849D+02) 20150, 10150, 40150              02920816
        !           296: 40150      IF (AVD + 0.8519564840D+02) 10150, 10150, 20150              02930816
        !           297: 10150      IVPASS = IVPASS + 1                                          02940816
        !           298:            WRITE (NUVI, 80002) IVTNUM                                   02950816
        !           299:            GO TO 0151                                                   02960816
        !           300: 20150      IVFAIL = IVFAIL + 1                                          02970816
        !           301:            DVCORR = -85.195648440779690309D+00                          02980816
        !           302:            WRITE (NUVI, 80031) IVTNUM, AVD, DVCORR                      02990816
        !           303:  0151      CONTINUE                                                     03000816
        !           304: CT016*  TEST 16                                                         03010816
        !           305:            IVTNUM = 16                                                  03020816
        !           306:         AVD = DLOG(8.0D0) + DLOG(0.125D0)                               03030816
        !           307:            IF (AVD + 0.5000000000D-09) 20160, 10160, 40160              03040816
        !           308: 40160      IF (AVD - 0.5000000000D-09) 10160, 10160, 20160              03050816
        !           309: 10160      IVPASS = IVPASS + 1                                          03060816
        !           310:            WRITE (NUVI, 80002) IVTNUM                                   03070816
        !           311:            GO TO 0161                                                   03080816
        !           312: 20160      IVFAIL = IVFAIL + 1                                          03090816
        !           313:            DVCORR = 0.00000000000000D+00                                03100816
        !           314:            WRITE (NUVI, 80031) IVTNUM, AVD, DVCORR                      03110816
        !           315:  0161      CONTINUE                                                     03120816
        !           316: C*****                                                                  03130816
        !           317: CBB** ********************** BBCSUM0  **********************************03140816
        !           318: C**** WRITE OUT TEST SUMMARY                                            03150816
        !           319: C****                                                                   03160816
        !           320:       IVTOTN = IVPASS + IVFAIL + IVDELE + IVINSP                        03170816
        !           321:       WRITE (I02, 90004)                                                03180816
        !           322:       WRITE (I02, 90014)                                                03190816
        !           323:       WRITE (I02, 90004)                                                03200816
        !           324:       WRITE (I02, 90020) IVPASS                                         03210816
        !           325:       WRITE (I02, 90022) IVFAIL                                         03220816
        !           326:       WRITE (I02, 90024) IVDELE                                         03230816
        !           327:       WRITE (I02, 90026) IVINSP                                         03240816
        !           328:       WRITE (I02, 90028) IVTOTN, IVTOTL                                 03250816
        !           329: CBE** ********************** BBCSUM0  **********************************03260816
        !           330: CBB** ********************** BBCFOOT0 **********************************03270816
        !           331: C**** WRITE OUT REPORT FOOTINGS                                         03280816
        !           332: C****                                                                   03290816
        !           333:       WRITE (I02,90016) ZPROG, ZPROG                                    03300816
        !           334:       WRITE (I02,90018) ZPROJ, ZNAME, ZTAPE, ZTAPED                     03310816
        !           335:       WRITE (I02,90019)                                                 03320816
        !           336: CBE** ********************** BBCFOOT0 **********************************03330816
        !           337: CBB** ********************** BBCFMT0A **********************************03340816
        !           338: C**** FORMATS FOR TEST DETAIL LINES                                     03350816
        !           339: C****                                                                   03360816
        !           340: 80000 FORMAT (1H ,2X,I3,4X,7HDELETED,32X,A31)                           03370816
        !           341: 80002 FORMAT (1H ,2X,I3,4X,7H PASS  ,32X,A31)                           03380816
        !           342: 80004 FORMAT (1H ,2X,I3,4X,7HINSPECT,32X,A31)                           03390816
        !           343: 80008 FORMAT (1H ,2X,I3,4X,7H FAIL  ,32X,A31)                           03400816
        !           344: 80010 FORMAT (1H ,2X,I3,4X,7H FAIL  ,/,1H ,15X,10HCOMPUTED= ,           03410816
        !           345:      1I6,/,1H ,15X,10HCORRECT=  ,I6)                                    03420816
        !           346: 80012 FORMAT (1H ,2X,I3,4X,7H FAIL  ,/,1H ,16X,10HCOMPUTED= ,           03430816
        !           347:      1E12.5,/,1H ,16X,10HCORRECT=  ,E12.5)                              03440816
        !           348: 80018 FORMAT (1H ,2X,I3,4X,7H FAIL  ,/,1H ,16X,10HCOMPUTED= ,           03450816
        !           349:      1A21,/,1H ,16X,10HCORRECT=  ,A21)                                  03460816
        !           350: 80020 FORMAT (1H ,16X,10HCOMPUTED= ,A21,1X,A31)                         03470816
        !           351: 80022 FORMAT (1H ,16X,10HCORRECT=  ,A21,1X,A31)                         03480816
        !           352: 80024 FORMAT (1H ,16X,10HCOMPUTED= ,I6,16X,A31)                         03490816
        !           353: 80026 FORMAT (1H ,16X,10HCORRECT=  ,I6,16X,A31)                         03500816
        !           354: 80028 FORMAT (1H ,16X,10HCOMPUTED= ,E12.5,10X,A31)                      03510816
        !           355: 80030 FORMAT (1H ,16X,10HCORRECT=  ,E12.5,10X,A31)                      03520816
        !           356: 80050 FORMAT (1H ,48X,A31)                                              03530816
        !           357: CBE** ********************** BBCFMT0A **********************************03540816
        !           358: CBB** ********************** BBCFMAT1 **********************************03550816
        !           359: C**** FORMATS FOR TEST DETAIL LINES - FULL LANGUAGE                     03560816
        !           360: C****                                                                   03570816
        !           361: 80031 FORMAT (1H ,2X,I3,4X,7H FAIL  ,/,1H ,16X,10HCOMPUTED= ,           03580816
        !           362:      1D17.10,/,1H ,16X,10HCORRECT=  ,D17.10)                            03590816
        !           363: 80033 FORMAT (1H ,16X,10HCOMPUTED= ,D17.10,10X,A31)                     03600816
        !           364: 80035 FORMAT (1H ,16X,10HCORRECT=  ,D17.10,10X,A31)                     03610816
        !           365: 80037 FORMAT (1H ,16X,10HCOMPUTED= ,1H(,E12.5,2H, ,E12.5,1H),6X,A31)    03620816
        !           366: 80039 FORMAT (1H ,16X,10HCORRECT=  ,1H(,E12.5,2H, ,E12.5,1H),6X,A31)    03630816
        !           367: 80041 FORMAT (1H ,16X,10HCOMPUTED= ,1H(,F12.5,2H, ,F12.5,1H),6X,A31)    03640816
        !           368: 80043 FORMAT (1H ,16X,10HCORRECT=  ,1H(,F12.5,2H, ,F12.5,1H),6X,A31)    03650816
        !           369: 80045 FORMAT (1H ,2X,I3,4X,7H FAIL  ,/,1H ,16X,10HCOMPUTED= ,           03660816
        !           370:      11H(,F12.5,2H, ,F12.5,1H)/,1H ,16X,10HCORRECT=  ,                  03670816
        !           371:      21H(,F12.5,2H, ,F12.5,1H))                                         03680816
        !           372: CBE** ********************** BBCFMAT1 **********************************03690816
        !           373: CBB** ********************** BBCFMT0B **********************************03700816
        !           374: C**** FORMAT STATEMENTS FOR PAGE HEADERS                                03710816
        !           375: C****                                                                   03720816
        !           376: 90002 FORMAT (1H1)                                                      03730816
        !           377: 90004 FORMAT (1H )                                                      03740816
        !           378: 90006 FORMAT (1H ,20X,31HFEDERAL SOFTWARE TESTING CENTER)               03750816
        !           379: 90007 FORMAT (1H ,19X,34HFORTRAN COMPILER VALIDATION SYSTEM)            03760816
        !           380: 90008 FORMAT (1H ,21X,A13,A17)                                          03770816
        !           381: 90009 FORMAT (1H ,/,2H *,A5,6HBEGIN*,12X,15HTEST RESULTS - ,A5,/)       03780816
        !           382: 90010 FORMAT (1H ,8X,16HTEST DATE*TIME= ,A17,15H  -  COMPILER= ,A20)    03790816
        !           383: 90013 FORMAT (1H ,8H TEST   ,10HPASS/FAIL ,6X,17HDISPLAYED RESULTS,     03800816
        !           384:      1       7X,7HREMARKS,24X)                                          03810816
        !           385: 90014 FORMAT (1H ,46H----------------------------------------------,    03820816
        !           386:      1        33H---------------------------------)                     03830816
        !           387: 90015 FORMAT (1H ,48X,17HTHIS PROGRAM HAS ,I3,6H TESTS,/)               03840816
        !           388: C****                                                                   03850816
        !           389: C**** FORMAT STATEMENTS FOR REPORT FOOTINGS                             03860816
        !           390: C****                                                                   03870816
        !           391: 90016 FORMAT (1H ,/,2H *,A5,4HEND*,14X,14HEND OF TEST - ,A5,/)          03880816
        !           392: 90018 FORMAT (1H ,A13,13X,A20,7H   *   ,A10,1H/,                        03890816
        !           393:      1        A13)                                                      03900816
        !           394: 90019 FORMAT (1H ,26HFOR OFFICIAL USE ONLY     ,35X,15HCOPYRIGHT  1982) 03910816
        !           395: C****                                                                   03920816
        !           396: C**** FORMAT STATEMENTS FOR RUN SUMMARY                                 03930816
        !           397: C****                                                                   03940816
        !           398: 90020 FORMAT (1H ,21X,I5,13H TESTS PASSED)                              03950816
        !           399: 90022 FORMAT (1H ,21X,I5,13H TESTS FAILED)                              03960816
        !           400: 90024 FORMAT (1H ,21X,I5,14H TESTS DELETED)                             03970816
        !           401: 90026 FORMAT (1H ,21X,I5,25H TESTS REQUIRE INSPECTION)                  03980816
        !           402: 90028 FORMAT (1H ,21X,I5,4H OF ,I3,15H TESTS EXECUTED)                  03990816
        !           403: CBE** ********************** BBCFMT0B **********************************04000816
        !           404: C*****                                                                  04010816
        !           405: C*****    END OF TEST SEGMENT 182                                       04020816
        !           406:       STOP                                                              04030816
        !           407:       END                                                               04040816
        !           408:                                                                         04050816

unix.superglobalmegacorp.com

This archive runs on limited infrastructure. Preserving old code on modern bandwidth. Automated agents are requested to crawl responsibly.