Annotation of coherent/a/usr/man/COHERENT/getty, revision 1.1

1.1     ! root        1: 
        !             2: 
        !             3: getty                   System Maintenance                  getty
        !             4: 
        !             5: 
        !             6: 
        !             7: 
        !             8: Terminal initialization
        !             9: 
        !            10: /eettcc/ggeettttyy _t_y_p_e
        !            11: 
        !            12: The initialization  process init invokes getty  for each terminal
        !            13: indicated in the file /etc/ttys.  getty tries to read a user name
        !            14: from the terminal which  is the standard input, adapting its mode
        !            15: settings  accordingly.  Then  getty invokes  login with  the name
        !            16: read.  This  process may  set delays,  mapping of upper  to lower
        !            17: case,  speed, and  whether  the terminal  normally uses  carriage
        !            18: return or linefeed to terminate input.
        !            19: 
        !            20: If the terminal baud rate  is wrong, the login message printed by
        !            21: getty will appear garbled.  If the specified type indicates vari-
        !            22: able speeds, as described  below, hitting BREAK will try the next
        !            23: speed.
        !            24: 
        !            25: init passes  the third character in a line  of the file /etc/ttys
        !            26: as the  type argument to  getty.  type conveys  information about
        !            27: the  terminal port.   An upper-case  letter in the  range A  to S
        !            28: specifies a hard-wired baud rate, as indicated in the header file
        !            29: <sgtty.h>.  Other  characters specify a range  of speeds suitable
        !            30: to a  dial-in modem.   The following variable-speed  settings are
        !            31: recognized:
        !            32: 
        !            33: 00  Cycles  through speeds 300,  1200, 150, and 110  baud, in that
        !            34:    order.  This is a good default setting for dial-in ports.
        !            35: 
        !            36: -  Teletype model 33, fixed at 110 baud.
        !            37: 
        !            38: 11  Teletype model 37, fixed at 150 baud.
        !            39: 
        !            40: 22  9600 baud with delays (e.g., Tektronix 4104).
        !            41: 
        !            42: 33  Cycles  between 2400, 1200,  and 300 baud.  This  is used with
        !            43:    2400-bps modems.
        !            44: 
        !            45: 44  DECwriter (LA36) with delays.
        !            46: 
        !            47: 55  Like 3, but starts at 300 baud.
        !            48: 
        !            49: getty  recognizes the following  fixed-speed settings,  for hard-
        !            50: wired terminals:
        !            51: 
        !            52:         AA       50 baud
        !            53:         BB       75 baud
        !            54:         CC       110 baud
        !            55:         DD       134 baud
        !            56:         EE       150 baud
        !            57:         FF       200 baud
        !            58:         GG       300 baud
        !            59:         HH       600 baud
        !            60:         II       1200 baud
        !            61:         JJ       1800 baud
        !            62: 
        !            63: 
        !            64: COHERENT Lexicon                                           Page 1
        !            65: 
        !            66: 
        !            67: 
        !            68: 
        !            69: getty                   System Maintenance                  getty
        !            70: 
        !            71: 
        !            72: 
        !            73:         KK       2000 baud
        !            74:         LL       2400 baud
        !            75:         MM       3600 baud
        !            76:         NN       4800 baud
        !            77:         OO       7200 baud
        !            78:         PP       9600 baud
        !            79:         QQ       19200 baud
        !            80:         RR       EXT
        !            81:         SS       EXT
        !            82: 
        !            83: ***** Files *****
        !            84: 
        !            85: /etc/tty
        !            86: <sgtty.h>
        !            87: 
        !            88: ***** See Also *****
        !            89: 
        !            90: init, ioctl(), login, sgtty.h, system maintenance, stty, ttys
        !            91: 
        !            92: 
        !            93: 
        !            94: 
        !            95: 
        !            96: 
        !            97: 
        !            98: 
        !            99: 
        !           100: 
        !           101: 
        !           102: 
        !           103: 
        !           104: 
        !           105: 
        !           106: 
        !           107: 
        !           108: 
        !           109: 
        !           110: 
        !           111: 
        !           112: 
        !           113: 
        !           114: 
        !           115: 
        !           116: 
        !           117: 
        !           118: 
        !           119: 
        !           120: 
        !           121: 
        !           122: 
        !           123: 
        !           124: 
        !           125: 
        !           126: 
        !           127: 
        !           128: 
        !           129: 
        !           130: COHERENT Lexicon                                           Page 2
        !           131: 
        !           132: 

unix.superglobalmegacorp.com

This archive runs on limited infrastructure. Preserving old code on modern bandwidth. Automated agents are requested to crawl responsibly.