Annotation of ntddk/src/comm/parallel/parlog.mc, revision 1.1.1.1

1.1       root        1: ;/*++ BUILD Version: 0001    // Increment this if a change has global effects
                      2: ;
                      3: ;Copyright (c) 1992, 1993  Microsoft Corporation
                      4: ;
                      5: ;Module Name:
                      6: ;
                      7: ;    ntiologc.h
                      8: ;
                      9: ;Abstract:
                     10: ;
                     11: ;    Constant definitions for the I/O error code log values.
                     12: ;
                     13: ;Author:
                     14: ;
                     15: ;    Tony Ercolano (Tonye) 12-23-1992
                     16: ;
                     17: ;Revision History:
                     18: ;
                     19: ;--*/
                     20: ;
                     21: ;#ifndef _PARLOG_
                     22: ;#define _PARLOG_
                     23: ;
                     24: ;//
                     25: ;//  Status values are 32 bit values layed out as follows:
                     26: ;//
                     27: ;//   3 3 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1
                     28: ;//   1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0
                     29: ;//  +---+-+-------------------------+-------------------------------+
                     30: ;//  |Sev|C|       Facility          |               Code            |
                     31: ;//  +---+-+-------------------------+-------------------------------+
                     32: ;//
                     33: ;//  where
                     34: ;//
                     35: ;//      Sev - is the severity code
                     36: ;//
                     37: ;//          00 - Success
                     38: ;//          01 - Informational
                     39: ;//          10 - Warning
                     40: ;//          11 - Error
                     41: ;//
                     42: ;//      C - is the Customer code flag
                     43: ;//
                     44: ;//      Facility - is the facility code
                     45: ;//
                     46: ;//      Code - is the facility's status code
                     47: ;//
                     48: ;
                     49: MessageIdTypedef=NTSTATUS
                     50: 
                     51: SeverityNames=(Success=0x0:STATUS_SEVERITY_SUCCESS
                     52:                Informational=0x1:STATUS_SEVERITY_INFORMATIONAL
                     53:                Warning=0x2:STATUS_SEVERITY_WARNING
                     54:                Error=0x3:STATUS_SEVERITY_ERROR
                     55:               )
                     56: 
                     57: FacilityNames=(System=0x0
                     58:                RpcRuntime=0x2:FACILITY_RPC_RUNTIME
                     59:                RpcStubs=0x3:FACILITY_RPC_STUBS
                     60:                Io=0x4:FACILITY_IO_ERROR_CODE
                     61:                Parallel=0x7:FACILITY_PARALLEL_ERROR_CODE
                     62:               )
                     63: 
                     64: 
                     65: 
                     66: MessageId=0x0001 Facility=Parallel Severity=Warning SymbolicName=PAR_UNREPORTED_IRQL_CONFLICT
                     67: Language=English
                     68: Another driver on the system, which did not report its resources, has already claimed the interrupt used by %1.
                     69: The driver will switch this port from interrupt driven to poll driven.
                     70: .
                     71: 
                     72: MessageId=0x0002 Facility=Parallel Severity=Informational SymbolicName=PAR_REPORTED_IRQL_CONFLICT
                     73: Language=English
                     74: Another driver on the system has already claimed the interrupt used by %1.
                     75: The driver will switch this port from interrupt driven to poll driven.
                     76: .
                     77: 
                     78: MessageId=0x0003 Facility=Parallel Severity=Error SymbolicName=PAR_INSUFFICIENT_RESOURCES
                     79: Language=English
                     80: Not enough memory was available to allocate internal storage needed for the device %1.
                     81: .
                     82: 
                     83: MessageId=0x0004 Facility=Parallel Severity=Error SymbolicName=PAR_REGISTERS_NOT_MAPPED
                     84: Language=English
                     85: The hardware locations for %1 could not be translated to something the memory management system could understand.
                     86: .
                     87: 
                     88: MessageId=0x0005 Facility=Parallel Severity=Error SymbolicName=PAR_ADDRESS_CONFLICT
                     89: Language=English
                     90: The hardware addresses for %1 are already in use by another device.
                     91: .
                     92: 
                     93: MessageId=0x0006 Facility=Parallel Severity=Error SymbolicName=PAR_NOT_ENOUGH_CONFIG_INFO
                     94: Language=English
                     95: Some firmware configuration information was incomplete.
                     96: .
                     97: 
                     98: MessageId=0x0007 Facility=Parallel Severity=Error SymbolicName=PAR_NO_PARAMETERS_INFO
                     99: Language=English
                    100: No Parameters subkey was found for user defined data.  This is odd, and it also means no user configuration can be found.
                    101: .
                    102: 
                    103: MessageId=0x0008 Facility=Parallel Severity=Error SymbolicName=PAR_UNABLE_TO_ACCESS_CONFIG
                    104: Language=English
                    105: Specific user configuration data is unretrievable.
                    106: .
                    107: 
                    108: MessageId=0x0009 Facility=Parallel Severity=Error SymbolicName=PAR_UNKNOWN_BUS
                    109: Language=English
                    110: The bus type for the port is not recognizable.
                    111: .
                    112: 
                    113: MessageId=0x000A Facility=Parallel Severity=Error SymbolicName=PAR_BUS_NOT_PRESENT
                    114: Language=English
                    115: The bus type for the port is not available on this computer.
                    116: .
                    117: 
                    118: MessageId=0x000B Facility=Parallel Severity=Error SymbolicName=PAR_BUS_INTERRUPT_CONFLICT
                    119: Language=English
                    120: The bus specified for the port does not support the specified method of interrupt.
                    121: .
                    122: 
                    123: MessageId=0x000C Facility=Parallel Severity=Error SymbolicName=PAR_INVALID_USER_CONFIG
                    124: Language=English
                    125: User configuration data does not contain all required information.
                    126: .
                    127: 
                    128: MessageId=0x000D Facility=Parallel Severity=Informational SymbolicName=PAR_USER_OVERRIDE
                    129: Language=English
                    130: User configuration data is overriding firmware configuration data.
                    131: .
                    132: 
                    133: MessageId=0x000E Facility=Parallel Severity=Error SymbolicName=PAR_DEVICE_TOO_HIGH
                    134: Language=English
                    135: The user specified port is way too high in physical memory.
                    136: .
                    137: 
                    138: MessageId=0x000F Facility=Parallel Severity=Error SymbolicName=PAR_CONTROL_OVERLAP
                    139: Language=English
                    140: The control registers for the port overlaps with a previous ports control registers.
                    141: .
                    142: 
                    143: MessageId=0x0010 Facility=Parallel Severity=Warning SymbolicName=PAR_NO_SYMLINK_CREATED
                    144: Language=English
                    145: Unable to create the symbolic link for %1.
                    146: .
                    147: 
                    148: MessageId=0x0011 Facility=Parallel Severity=Warning SymbolicName=PAR_NO_DEVICE_MAP_CREATED
                    149: Language=English
                    150: Unable to create the device map entry for %1.
                    151: .
                    152: 
                    153: MessageId=0x0012 Facility=Parallel Severity=Warning SymbolicName=PAR_NO_DEVICE_MAP_DELETED
                    154: Language=English
                    155: Unable to delete the device map entry for %1.
                    156: .
                    157: 
                    158: MessageId=0x0013 Facility=Parallel Severity=Informational SymbolicName=PAR_DISABLED_PORT
                    159: Language=English
                    160: Disabling port %1 as requested by the configuration data.
                    161: .
                    162: 
                    163: MessageId=0x0014 Facility=Parallel Severity=Error SymbolicName=PAR_INTERRUPT_STORM
                    164: Language=English
                    165: Disabling port %1 interrupts because we were being blasted by unexpected interrupts.
                    166: .
                    167: 
                    168: ;#endif /* _NTIOLOGC_ */

unix.superglobalmegacorp.com

This archive runs on limited infrastructure. Preserving old code on modern bandwidth. Automated agents are requested to crawl responsibly.