Annotation of researchv10no/cmd/tbl/tmp/sample30, revision 1.1

1.1     ! root        1: .1C
        !             2: .ft3
        !             3: .ps 10
        !             4: .vs 12
        !             5: .ce 3
        !             6: TABLE B
        !             7: .sp 0.5
        !             8: RECOMMENDED WORK ALLEY WIDTHS FOR BOTH ABOVE- AND
        !             9: BELOW-SURFACE CEFs
        !            10: .sp 0.5
        !            11: .TS H
        !            12: box expand;
        !            13: cw(2.3i)p8f3 |cp8f3 |cp8f3
        !            14: ^ |cp8f3 |cp8f3 .
        !            15: .vs 10
        !            16: .sp 1
        !            17: TYPE OF ACTIVITY*      MINUMUM WIDTH   RECOMMENDED WIDTH
        !            18:        (Inches)        (Inches)
        !            19: _
        !            20: .sp 0.5
        !            21: .TH
        !            22: .T&
        !            23: lp10f1 |np10f1 |np10f1 .
        !            24: .vs 12
        !            25: T{
        !            26: .na
        !            27: .ft2
        !            28: Low activity
        !            29: .ft1
        !            30: (no through passage) with cable positioned on one or both sides 
        !            31: of the work area.
        !            32: T}     36\(dg  40\(dg
        !            33: _
        !            34: .sp 0.5
        !            35: T{
        !            36: .ft2
        !            37: Low activity
        !            38: .ft1
        !            39: with permanently installed rolling ladder, and cable
        !            40: on only one side of the alley (includes 18 inches for ladder width).
        !            41: T}     54      60
        !            42: _
        !            43: .sp 0.5
        !            44: T{
        !            45: .ft2
        !            46: Moderate activity
        !            47: .ft1
        !            48: with clearance for passage of craft person behind
        !            49: seated splicer (includes 20 inches for sideway passage of
        !            50: other craft persons) and cable on one or both sides of the work area.
        !            51: T}     56      62
        !            52: _
        !            53: .sp 0.5
        !            54: T{
        !            55: .ft2
        !            56: Heavy activity
        !            57: .ft1
        !            58: with clearance for passage of both outside and central
        !            59: office workers behind seated splicer (includes a minimum 27 inches for
        !            60: passage of other persons and/or central office work operations).
        !            61: T}     63      70
        !            62: .ad
        !            63: .TE
        !            64: .ft1
        !            65: .sp 1
        !            66: .in 0.4i
        !            67: .IP *\0
        !            68: Activity refers to the frequency of passage of other craft persons past the
        !            69: splicer's work space.  (Low \(<= one per hour; moderate \(<= five per hour;
        !            70: heavy \0\0 five per hour.)
        !            71: .IP
        !            72: .in 0
        !            73: .sp 1
        !            74: .in 0.4i
        !            75: .IP \(dg\0
        !            76: In central office buildings where the CEF is positioned such that other
        !            77: building area occupants must pass through the CEF area to exit, then the
        !            78: minimum distance between the equipment frame and the nearest obstruction
        !            79: shall not be less than 44 inches.
        !            80: .IP
        !            81: .in 0
        !            82: .sp 2

unix.superglobalmegacorp.com

This archive runs on limited infrastructure. Preserving old code on modern bandwidth. Automated agents are requested to crawl responsibly.